SUGGESTED SPECIFICATIONS

The heater(s) shall be Dura-Power Commercial Electric Model Number _______________ as manufactured by A.O. Smith Water Products Company
or equivalent. Heater(s) shall be rated at ______________ KW ________ V _____________ phase, 60 cycle AC listed by Canadian Standards
Association.  Tank(s) shall be ________ gallon (Liter) capacity.  Heater(s) shall have 150 psi (1034 kPa) working pressure and be equipped with
extruded high density anode. All internal surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition
that has been fused to steel by firing at a temperature range of 1400°F to 1600°F (760° to 870°C).  Electric heating elements shall be low watt density
with incoloy sheath and 1" screw-in type.  Each element shall be controlled by an individually mounted thermostat and high temperature cut-off
switch.  All internal circuits shall be fused (optional).  The outer jacket shall be of baked enamel finish and shall be provided with full size control
compartment for performance of service and maintenance through hinged front panel and shall enclose the tank with vermin proof foam insulation.
Electrical junction box with heavy duty terminal block shall be provided.  The drain valve shall be located in the front for ease of servicing.  Heater
tank shall have a three year limited warranty as outlined in the written warranty.  Manufacturer shall supply ASME rated temperature and pressure
relief valve.  Fully illustrated instruction manual to be included.

RECOVERY CAPACITY IN GALLONS AT TEMPERATURE RISE OF

Standard

BTU/

30°F

40°F

50°F

60°F

70°F

80°F 90°F 100°F 110°F 120°F 130°F 140°F

kW Input

Hour

17°C

22°C

28°C

33°C

39°C

45°C 50°C

56°C

61°C

67°C

72°C

78°C

6

20,478

82

62

49

41

35

31

27

25

22

21

19

18

310

233

166

155

133

116

103

93

85

78

72

66

9

30,717

123

92

74

62

53

46

41

37

34

31

28

26

465

349

279

233

199

174

155

140

127

116

107

100

12

40,956

164

123

98

82

70

61

55

49

45

41

38

35

620

465

372

310

266

233

207

186

169

155

143

133

13.5

46,075

184

138

111

92

79

69

62

55

50

46

43

40

698

523

419

349

299

262

233

209

190

174

161

150

15

51,195

205

154

123

102

88

77

68

61

56

51

47

44

775

582

465

388

332

291

258

233

211

194

149

166

18

61,434

246

184

148

123

105

92

82

74

67

62

57

53

930

698

558

465

399

349

310

279

254

233

215

199

24

81,912

328

246

197

164

140

123

109

98

90

82

76

70

1241

930

744

620

532

465

414

372

338

310

286

266

27

92,151

369

276

221

185

158

138

123

111

101

92

85

79

1396

1047

938

609

509

523

465

410

391

340

322

299

30

102,390

410

307

246

205

176

154

137

123

112

102

95

88

1551

1163

930

775

665

582

517

465

423

388

358

332

36

122,868

492

369

295

246

211

184

164

148

134

123

113

105

1861

1396

1117

930

798

698

620

556

508

465

429

399

40.5

138,226

554

418

332

277

237

208

185

166

151

138

128

119

2094

1570

1256

1047

897

785

698

628

634

582

537

498

45

153,585

615

461

369

307

263

230

205

184

168

154

142

132

2326

1745

1398

1163

997

872

755

698

634

582

537

498

54

184,302

738

554

443

359

316

277

246

221

201

185

170

158

2791

2094

1675

1396

1196

1047

930

837

761

696

644

598

Figured at 1 KW (3413 BTU) = 4.1 Gallons at 100°F temperature rise.
NSF ratings may be obtained by multiplying the above figures by 0.98.

Tank

Dimensions

Inlet/

Approx. Ship.

 Model

Capacity

A

B

C

Outlet (NPT)

Wt. (Lbs.)

Number

gal.

litre

in.

cm

in.

cm

in.

cm

in.

cm

lb

kg

DRE-52

50

189

55 1/4

140.3

21 3/4

55.2

27 1/4

69.2

1 1/4

3.2

265

120

DRE-80

80

300

59 1/2

151.1

25 1/4

64.1

31 1/4

79.4

1 1/4

3.2

280

127

DRE-120

119

450

62 1/4

158.1

29 1/2

75.0

35 3/4

90.8

1 1/4

3.2

390

177

Model Numbers

Number

Full Load Current In Amperes

KW

Tank Capacity in Gallons

Of

Element

Single Phase

 Three Phase

Input

50

80

119

Elements

Wattage

208V

240V

277V

480V

208V

240V

480V

6

 DRE-52-6

 DRE-80-6

 DRE-120-6

3

2,000

28.8

25.0

21.7

12.5

16.7

14.4

7.2

9

 DRE-52-9

 DRE-80-9

 DRE-120-9

3

3,000

43.3

37.5

32.5

18.8

25.0

21.7

10.8

12

 DRE-52-12

 DRE-80-12

 DRE-120-12

3

4,000

57.7

50.0

43.3

25.0

33.3

28.9

14.4

13.5

 DRE-52-13.5

 DRE-80-13.5

 DRE-120-13.5

3

4,500

64.9

56.3

48.7

28.1

37.5

32.5

16.2

15

 DRE-52-15

 DRE-80-15

 DRE-120-15

3

5,000

72.1

62.5

54.2

31.3

41.6

36.1

18.0

18

 DRE-52-18

 DRE-80-18

 DRE-120-18

  3*

6,000

86.5

75.0

65.0

37.5

50.0

43.3

21.7

24

 DRE-52-24

 DRE-80-24

 DRE-120-24

6

4,000

115.4

100.0

86.6

50.0

66.6

57.7

28.9

27

 DRE-52-27

 DRE-80-27

 DRE-120-27

6

4,500

129.8

112.5

97.5

56.3

74.9

65.0

32.5

30

 DRE-52-30

 DRE-80-30

 DRE-120-30

6

5,000

144.2

125.0

108.3

62.5

83.3

72.2

36.1

36

 DRE-52-36

 DRE-80-36

 DRE-120-36

  6*

6,000

173.1

150.0

130.0

75.0

99.9

86.6

43.3

40.5

 DRE-52-40.5

 DRE-80-40.5

 DRE-120-40.5

9

4,500

194.7

168.8

146.2

84.4

112.4

97.4

48.7

45

 DRE-52-45

 DRE-80-45

 DRE-120-45

9

5,000

216.3

187.5

162.5

93.8

124.9

108.3

54.1

54

 DRE-52-54

 DRE-80-54

 DRE-120-54

9

6,000

N/A

225.0

194.9

112.5

149.9

129.9

65.0

*208 volt models may contain three (3) additional elements.