10
1.4
Technical Data
Type
DRE 52-9
DRE 52-18 DRE 52-36
Tank capacity litres
200
200
200
Number of elements -
3
3
6
Power 380V-3F kW
7.6
15.2
30.3
Power 400V-3F kW
8.4
16.8
33.6
Power 414V-3F kW
9.0
18.0
36.0
Heating time up to 60C*
(400/414V) min
83/78
42/39
21/19
Heating time up to 40C*
(400/414V) min
50/47
25/23
12/12
Tap capacity 1st hour 60°C**
(400/414V) litres
329/339
467/486
741/781
Tap capacity continuous 60°C**
(400/414V) litres/hour
145/155
289/310
578/619
Tap capacity 1st hour 40°C**
litres
549/565
778/810
1235/1300
Tap capacity continuous 40°C
litres/hour
241/258
482/516
963/1032
Weight kg
73
73
73
Type
DRE 80-9
DRE 80-18 DRE 80-36 DRE 80-54
Tank capacity litres
300
300
300
300
Number of elements -
3
3
6
9
Power 380V-3F kW
7.6
15.2
30.3
45.5
Power 400V-3F kW
8.4
16.8
33.6
50.4
Power 414V-3F kW
9.0
18.0
36.0
54.0
Heating time up to 60C*
(400/414V) min
125/116
62/58
31/29
21/19
Heating time up to 40C*
(400/414V) min
75/70
37/35
19/17
12/12
Tap capacity 1st hour 60°C**
(400/414V) litres
425/435
563/582
837/876
1112/1170
Tap capacity continuous 60°C**
(400/414V) litres/hour
145/155
289/310
578/619
867/929
Tap capacity 1st hour 40°C**
litres
709/725
938/970
1395/1460
1853/1951
Tap capacity continuous 40°C
litres/hour
241/258
482/516
963/1032
1445/1548
Weight kg
110
110
110
110
Summary of Contents for DURA-Power DRE-52
Page 25: ...25...
Page 26: ...0310 145_R2...