12
Troubleshooting
12.1
Errors and warnings
The water heater can have three different kinds of errors and warnings:
•
General errors (see 12.1.1), which are not displayed
•
Displayed errors (see 12.1.2), which are divided in two different groups:
-
Lock out errors: when the cause is removed, you can reset the error to resume
operation. The displayed code and the back-light of the display blink.
-
Blocking errors: when the cause is removed, the error resets automatically to
resume operation. The code is displayed continuously and the back-light of the
display blinks.
•
Displayed warnings (see 12.1.3)
Note
It is possible to view the error history of the water heater, refer to Error history (see
10.4).
12.1.1
General errors
Note
For the coding of the connections, refer to the Electrical wiring diagram (see 13.4).
Indication
Cause
Measure
Gas smell
There is a gas leak
-
Close the mains gas valve at once.
-
Do not operate any switches.
-
No naked flames.
-
Ventilate the boiler room.
-
Immediately contact your installation
engineer or your local gas company.
The display is off
The water heater is off.
Turn on the water heater (see 4.2).
There is no supply voltage.
Make sure that:
-
the control switch is set to I.
-
the isolator is in ON position.
-
there is power on the isolator.
-
there is power to the electrical
connector block.
The measured voltage must be
230 V
AC
(-15%, +10%).
Defective fuse(s)
Replace the fuse(s).
n
n
0312266_INNOVO_UKUK_
V5.1, 2022-07-12
71
Summary of Contents for Innovo IR 12-160
Page 6: ...6 ...
Page 13: ...User part 0312266_INNOVO_UKUK_V5 1 2022 07 12 13 ...
Page 14: ...14 ...
Page 16: ...16 User part ...
Page 18: ...18 User part ...
Page 24: ...24 User part ...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V5 1 2022 07 12 27 ...
Page 28: ...28 User part ...
Page 36: ...36 Installation Maintenance and Service part ...
Page 56: ...56 Installation Maintenance and Service part ...
Page 58: ...58 Installation Maintenance and Service part ...
Page 70: ...70 Installation Maintenance and Service part ...
Page 83: ...0312266_INNOVO_UKUK_V5 1 2022 07 12 83 ...
Page 87: ...13 4 Electrical wiring diagram 0312266_INNOVO_UKUK_V5 1 2022 07 12 87 ...
Page 89: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V5 1 2022 07 12 89 ...
Page 90: ......
Page 91: ......
Page 94: ...92 Installation Maintenance and Service part ...