12
Product Characteristic
Physical filtration compounds have been applied to the machine as the purification principle:
Pre-filters can capture substances in the air, such as hair and large particle pollutants; also help to extend
the lifespan of main-filters.
Main-filters are constructed by HEPA (High-Efficiency Particulate Arrestance) and Modified Actived Carbon.
This combination can capture the size of solid pollutants above
0.3μm (Micrometer);
also remove
decoration pollution, such as formaldehyde, methylbenzene and TVOC. An extra layer of anti-bacteria has
been applied to the HEPA to inhibit bacteria to grow for healthiness.
Filters Installation
1.
Pre-filters installation
2.
Main-filters installation
1
Disconnect the power
supply & open the inlet
louver on both sides.
2 The handle on the filter should toward
inlet louver, and replace both pre-filters
together as shown above.
3
Close both inlet louvers after
replacement of pre-filters.
1
Open the top cover by
pressing the lock on both
sides of the unit.
2 Pull up main filters as
shown above, and
remove filters’ packing.
3 The arrowhead on filters and
unit should point to each other,
insert filters as shown above.
4
Close the top
cover.
Note
:
Pre-filters have been pre-installed by factory; no installation is needed for the initial operation.
Important: The packing of main-filters must be removed before the unit is operated.