•  Variable speed drill with  

1/4" bit (for drilling a hole  

on PVC drain pipe)

•  Open-end wrenches (11⁄16", 

13/16", 1"), adjustable  

wrench, or pliers

• Phillips head screwdriver

• Scissors or utility knife
• Towel and bucket
•  Food-grade silicon grease 

(optional)

•  Filter cartridge wrenches 

(included with the system)

Note: We recommend using 
an approved or certified 
professional if drilling is 
required. Basic plumbing 
knowledge is recommended 
prior to installing this unit.

AOW-4000 

REVERSE OSMOSIS

With Microbial and Pump

TABLE OF CONTENTS

Box Contents .........................................................................................................................................1 

Installation Guide ...............................................................................................................................2-9 

Initial Startup .......................................................................................................................................10

Digital Sensors .....................................................................................................................................11

Care and Maintenance ...................................................................................................................12-13 

Performance Data Sheet .....................................................................................................................14 

System Specifications .....................................................................................................................15-17

Warranty ..............................................................................................................................................18 

Spanish/Español ...................................................................................................................................19

A. O. Smith has obsessively engineered this filtration system for you to feature both Reverse 
Osmosis and Claryum

®

 filtration that reduces harmful contaminants – those you can see, smell 

and taste, and those you can’t – with no chemical additives. Whatever your water needs – from 
hydration to cooking, early morning coffee, smoothies, or soup, you will now have filtered water. 

Keep this owner’s manual to reference installation, troubleshooting  
and filter replacement information. 

If you need help or have a question, we’ve got you covered.  
Give us a call at 833.232.9711

BOX CONTENTS

1

Tools recommended for installation:

R    

DRAIN SADDLE WITH 
INSTALLATION PARTS 

S  

REMINERALIZER 
MOUNTING BRACKET

MOUNTING SCREWS  

  (FOR REMINERALIZER 
  BRACKET AND SYSTEM 
 MANIFOLD)

TUBING

CABLE TIES

SPARE QUICK-CONNECT 

  FITTING LOCKS

X  

REDUCING ELBOW  
FITTINGS (2)

CARBON 

CLARYUM

®

MEMBRANE

REMINERALIZER WITH 

  MICROBIAL FILTER

FILTER HOUSING O-RINGS

PLUMBER'S TAPE

LEAK DETECTOR

HOUSING WRENCHES

WATER FEED ADAPTER

SYSTEM COVER

FILTER HOUSINGS (3)

RO MANIFOLD

FAUCET WITH  

  INSTALLATION PARTS

E  

STORAGE TANK

F  

TANK STAND

TANK SHUT-OFF VALVE

PREFILTER

Please read entire manual to ensure all parts listed are present before installation.

If any part is missing or damaged let us know by calling 833.232.9711.  

Do not attempt to install the filter. 

Summary of Contents for Pro AOW-4000

Page 1: ...NER S MANUAL Use this owner s manual to reference installation troubleshooting and filter replacement information If you need help or have a question we ve got you covered Give us a call at 833 232 97...

Page 2: ...ther manufacturers will also void your warranty Please visit www aosmith com wholesale for replacement parts Installation must comply with state and local ordinances A O Smith is not liable for conseq...

Page 3: ...those you can see smell and taste and those you can t with no chemical additives Whatever your water needs from hydration to cooking early morning coffee smoothies or soup you will now have filtered w...

Page 4: ...stem Manifold Remineralizer and Tank into the under sink cabinet or desired location to ensure adequate space and proper positioning 1 This system is designed to be installed under the sink but wherev...

Page 5: ...semble the quick connect tubing adapter to the faucet base threads 1 Identify drain outlet location Do not install the drain connector onto the same drainpipe as the garbage disposal If drain line mus...

Page 6: ...d with two clear covers on the ends of the membrane These covers are only included to protect the Membrane seals during shipping and they should be removed and disposed of before installation 2 Discon...

Page 7: ...Tank connection 1 4 white tubing Use a length of 1 4 white tubing to connect the System Manifold to the Storage Tank Insert one end of the tubing to the tank fitting on the System Manifold and the ot...

Page 8: ...he system will perform a brief startup flush and then return to normal service The system monitors the life of the five filter elements and notifies you when they need to be replaced The display shows...

Page 9: ...idges can lead to contamination that can cause an unsafe condition when the system restarts Replace with new filter cartridges before restarting the system Check that both O rings are assembled to the...

Page 10: ...ontrile 0 024 0 0006 98 dichloroacetontrile 0 0096 0 0002 98 trichloroacetontrile 0 015 0 0003 98 haloketones HK 1 1 dichloro 2 propanone 0 0072 0 0001 99 1 1 1 trichloro 2 propanone 0 0082 0 0003 96...

Page 11: ...see startup instructions this discoloration will end It is possible for the unit to become contaminated if it is not operated for a long period of time To prevent this from happening the system will...

Page 12: ...ons upon payment of 9 50 for shipping and handling per incident How to get service To receive service under this warranty you must contact A O Smith at 833 232 9711 or watertreatmentpro aosmith com wi...

Page 13: ...lta una pieza o alguna est da ada ll menos para avisarnos al 833 232 9711 No intente instalar el filtro Herramientas recomendadas para la instalaci n N CINTA DE TEFL N O DETECTOR DE FUGAS P LLAVES PAR...

Page 14: ...omo para que no se necesiten m s de 5 m 15 pies de tubo entre el sistema de OI y la llave El sistema de OI no se debe colocar a m s de 3 m 10 pies bajo la llave Una distancia o diferencia excesiva de...

Page 15: ...apriete en exceso ADAPTADOR DE ALIMENTACI N DE AGUA V LVULA DE CIERRE DEL TANQUE 25 PASO 4 Instalaci n del conector de drenaje 1 Identifique la ubicaci n de la salida de drenaje No instale el conecto...

Page 16: ...lave Deslice el escudo con la junta sobre la tuber a de drenaje hasta que quede asentado contra la llave 6 Coloque las tuber as en el orificio de instalaci n e inserte la llave en el orificio con el l...

Page 17: ...mbrana Estas cubiertas solo se incluyen para proteger los sellos de la membrana durante el env o y se deben retirar y desechar antes de la instalaci n 2 Desconecte el tubo blanco del conector de conex...

Page 18: ...1 4 para conectar el colector del sistema al tanque de almacenamiento Inserte un extremo del tubo en el conector del tanque del colector del sistema y el otro extremo en la v lvula de cierre de la par...

Page 19: ...ando y llenar el tanque de almacenamiento con agua purificada Mientras la unidad est en funcionamiento vuelva a verificar el sistema para encontrar fugas PROCEDIMIENTO DE ARRANQUE INICIAL 1 Cierre la...

Page 20: ...til del filtro de un cartucho despu s de que se reemplaza Para restablecer la vida til de un cartucho presione el bot n Select hasta que el cono del cartucho de filtro deseado parpadee Cuando haya sel...

Page 21: ...00001 99 heptachlor epoxide 0 0002 0 0107 0 0002 98 hexachlorobutadiene 0 044 0 001 98 hexachlorocyclopentadiene 0 05 0 060 0 000002 99 lindane 0 0002 0 055 0 00001 99 methoxychlor 0 04 0 050 0 0001 9...

Page 22: ...sistema reduce el ars nico pentavalente pero es posible que no elimine otras formas de ars nico Este sistema se debe usar en suministros de agua que contengan un cloro libre detectable residual en la...

Page 23: ...S EN EL ESTADO DE MASSACHUSETTS El Estado de Massachusetts exige que la instalaci n la realice un plomero con licencia y no permite el uso de v lvulas de silla Se debe cumplir con el C digo de plomer...

Reviews: