Triasoft Mini
Operating Modes
Mode 1 (Timer Mode) and Mode 2 (Meter Delayed Mode) Setting Chart
This section provides guidance for using different service settings to achieve the desired capacity.
The appliance has three operating modes: Timer mode, Meter Delayed mode, and Demand Immediate mode. All three modes are equipped with
Capacity Guard®, which ensures that a supply of conditioned water will be available even with excessive water usage.
• Mode 1 - Timer Mode
When the appliance is in Timer mode, it will regenerate based on the
frequency that is set, for example every two days or up to every 12 days.
The time of regeneration can be set.
• Mod 2 - Meter Delayed Mode
When the appliance is in Meter Delayed mode, it will regenerate based
on the actual water usage and the total capacity of the appliance. The
time that the regeneration takes place can be set, for example 2:00 a.m.
Should the total capacity be depleted before the set regeneration time, a
forced regeneration will occur.
• Mod 3 - Demand Immediate Mode
When the appliance is in Demand Immediate mode, it will regenerate
based on water usage alone. Regeneration will occur when the capacity
limit is reached.
• 72–96 hr Regen
If this value is set to Yes, the appliance will be forced to regenerate every
72–96 hours unless a regeneration based on water usage occurs within
the time interval.
Note:
The value should always be set to Yes if iron is present in the water.