background image

How to use

Technical Specifications

Troubleshooting

Electrical Safety

Even though these products are designed keeping highest safety standards in 

mind, there are certain Do’s and Dont’s which need to be followed while using 

these products.

•  Discard the first cycle of 

pure water, before you 

start using it for 

consumption.

•  Make sure to discard 

the water in the storage 

tank if you have not 

used the purifier for 

more than 2 days.

Notice

Your A. O. Smith       /        RO Water Purifier may not function at its desired 

capability if used incorrectly. This may not necessarily mean that the product is 

faulty. For instances like these, please follow the steps given below to 

troubleshoot the problem without the help from a certified technician. If the 

problem still persists, please call Customer care centre immediately.

Recommended input Feed water quality for the optimum 
performance of your product

  *  Flow rates depends on variable factors such as feed water pressure, feed water characteristics 

and condition of the membranes and filters.

 **  Recovery and TDS reduction percentages also depends on variable factors such as life and 

condition of the membranes and filters, feed water pressure, feed water characteristics etc.

 ***  If input pressure exceeds 30 psi, a pressure reducing valve needs to be installed at the feed line. 

If the pressure is lower than 7 psi, a booster pump needs to be installed. Ensure you buy them 
from A. O. Smith Company authorised service technician.

Power plug must be used with a 230 V 

outlet. It is recommended to connect 

the product to the power supply only 

with the plug that is provided with 

the purifier. Do not pull out or touch 

power plug with wet hands to avoid 

electrical shock.

1.  Turn ON the water connection 

through the ball valve.

3.  To dispense water from the 

storage tank, push and hold the 

water faucet lever.

4.  To dispense water continuously, 

lift up the water faucet lever for 

the continuous water flow. To stop 

the water flow, pull down the 

water faucet lever.

2.  Switch ON the power supply and 

press the power button of the 

purifier.

Make sure that the feed water is 

tested before installation. Do not 

install the product if the TDS and 

Hardness are more than that 

prescribed in the recommended feed 

water conditions (Refer Page 12).

Product should be installed only by 

A. O. Smith Company Authorised 

Service Technician. Do not open the 

purifier for cleaning the filters or for 

any part replacements. This must be 

done only by A. O. Smith Company 

Authorised Service Technician. 

Install the product away from direct 

sunlight.

7

8

9

10

12

13

14

11

Change in water taste   Has the purified water 

Drain the stored water from

(All models). 

been stored in the tank  the storage tank through

 

for long time? 

faucet.

 

RO membrane/filters 

Call Customer Care Centre

 

may require  

for RO membrane/filters

 

replacement. replacement.

 

Has the raw water   

Call Customer Care Centre.

 

quality changed? 

 

Check if there is no  

Switch OFF the Water

 

water flow through  

Purifier and call Customer

 

reject line. 

Care Centre.

Decreased flow of  

Check whether the tap/ 

  Open the tap/ball valve.

purified water 

ball valve is closed.

(All models). 

RO membrane/filters 

Call Customer Care Centre.

 

may be clogged or 

for RO membrane/filters

 

damaged. replacement.

Less/No reject water 

Check if the reject  

Clear the bent in the reject

(All models). 

Water tube is bent. 

water tube.

 

Check if the reject 

Switch OFF the Water

 

Water tube is blocked. 

Purifier and Call Customer

 

 

Care Centre.

Less/No purified 

Check whether there is 

If not, take the help of a

water (All models). 

water supply in the tap.  plumber to set it right.

 

Check whether tap/ball  Open the tap/ball valve.

 

valve is closed. 

 

Check if either Filter 

Call Customer Care Centre

 

change (        model  

for RO membrane/filters

 

only) is blinking. 

replacement.

 

None of the above. 

Call Customer Care Centre.

 

Problems 

Possible Cause(s) 

Solution

Water flow

Electrical Diagram

Safety Precautions

Figure 3

Figure 4

Figure 5

Figure 5

Figure 5

Figure 5

Figure 5

Figure 5

5.  To stop the water flow, pull down the 

water faucet lever to position 2 slowly 

and then to initial position. This avoids 

splashing of water. 

Figure 5

Figure 5

Figure 5

Faucet

Float Switch 

Storage Tank

Pump

RO

Sediment

filter

SCB filter™

Tap water

Ball Valve

Inlet water

3-way joint

Check

Valve

Low Pressure

Switch

Inlet Solenoid

valve

Flow 

Restrictor

Waste 

water

Pure

water

SCM-TECH™

Faucet

Float Switch 

Storage Tank

Pump

RO

Sediment

filter

SCB filter™

Tap water

Ball Valve

Inlet water

3-way joint

Check

Valve

Low Pressure

Switch

Inlet Solenoid

valve

Flow 

Restrictor

Flush

Solenoid

valve

Waste 

water

Pure

water

SCM-TECH™

ON

230V

CAUTION

TDS

METER

CAUTION

Parameter  

Limits

Total Dissolved Solids (TDS)  

Up to 2000 ppm

Total hardness  

Up to 500 ppm

Turbidity  

Up to 5 NTU

Iron 

0.3 ppm (max.)

Feed water pressure 

5 psi to 30 psi

Feed water temperature 

5°C to 45°C

RECOMMENDED FEED WATER QUALITY

SMPS

24 VDC

LPS

HPS

High water

level

GND

150V - 300V

50 Hz AC

P

N

Pump

Inlet

SV

LPS

Pump

SMPS

Inlet

SV

High

water

level

switch

Flush

SV

Display 

PCB

150V - 300V

50 Hz

1- f AC supply

P

N

Main Control Board

24V DC

GND

Position 1

Position 2

Position 3

Product Dimensions (H x D x W) 

460 mm x 260 mm x 380 mm

Net Weight 

8.5 kgs (approx.)

Gross Weight 

10 kgs (approx.)

Flow rate* 

Upto 15 litres per hour

Storage tank capacity 

5 litres (approx.)

Purification technology 

RO (Reverse Osmosis)

6 Stage Purifying Technology 

Sediment SCB filter (Sediment 

Carbon block) + Side Stream RO 

me SCM-TECH filter (Silver 

Activated Post MIN-TECH)

Membrane type 

Thin film composite RO membrane

Material of construction for  

Food safe, non-toxic, engineering grade

plastic parts 

plastics

Pump type 

Diaphragm pump, 24VDC, 0.26 Amps, 

Operating Pressure 125 psi (Max.)

Input Voltage 

150 – 300 VAC, 50 Hz

Power rating (Max) 

48 Watts

Pressure Rating*** 

5 psi to 30 psi

% Recovery** 

Upto 30%

TDS reduction** 

≥95% (approx.)

Input water temperature 

5°C to 45°C

Model 

A. O. Smith       / 

Tank full LED blinks 

Over flow error. 

Switch OFF the Water

continuously  

 

Purifier and call Customer 

(For        model). 

 

Care Centre. 

Power LED blinks 

Low pressure alarm is 

Check feed water supply

continuously 

triggered indicating  

to the purifier. If problem

(For        model). 

that the system input 

still persists, switch OFF

 

water pressure is not  

the Water Purifier and call

 

in the required range. 

Customer Care Centre.

Flush LED blinks 

RTC error. 

Switch OFF the Water

continuously  

 

Purifier and call Customer

(For        model). 

 

Care Centre.

Filter change LED 

RO membrane or filters   Call Customer Care Centre

blinks and unit is 

life is about to ends. 

for RO membrane or filters 

functioning  

 

replacement.

(For        model). 

 

Filter change LED 

RO membrane or filters  Switch OFF the Water

blinks and unit is not  life ends. 

Purifier and call Customer 

functioning  

 

Care Centre RO membrane 

(For        model). 

 

or filters replacement.

Problems 

Possible Cause(s) 

Solution

Reviews: