11
A3-P
It is advisable to install a filter on the air compressed system to obtain clean and lubricated
air. Use only silicone lubricating oil for pneumatic systems. The use of inadequate oil could
damage the valves.
Check the foot pedal operation when the wedge magazine is closed. The foot pedal
control is deactivated when the wedge magazine is opened.
4.6 PRELIMINARY CONTROLS
Before setting up the machine, execute checks to prevent mistakes or accidents during setup.
• Verify that machine has not been damaged.
• Verify the pipes integrity
4.7 MACHINE ARRANGEMENT
4.7.1 Wedges magazine loading
To load the wedge magazine proceed as follows:
• Move the claw pusher backwards by flipping the special lever
located on the right side of the machine working bench. This will
give you access to the wedge magazine (see fig. 7).
Picture 7
• Insert one wedge strip into the magazine. Make sure that the
sharpened edge of the wedges (glue side) faces up and that they
are loaded with the "V" of the wedges pointing in the direction
indicated in the figures 8 and 9. Check to see if the wedge size is
suitable with the type of claw-head mounted.
Picture 8
• Move the claw pusher forward by flipping the control lever (see fig.7)
Picture 9