background image

14

SR703 AMPLIFICADOR DE POTENCIA PARA CONTRATISTA

Español

ESPECIFICACIONES

SR703

Salida de Potencia Directa

8 ohms

120 Watts x 2

4 ohms

200 Watts x 2

2 ohms,1kHz,1%THD

300 Watts x 2

Mono Bridge 8 ohms, 1kHz, 1%THD

420 Watts

Mono Bridge 4 ohms, 1kHz, 1%THD

540 Watts

Salida de Voltaje Aislada Constante

200V o 140V Bridge

300 Watts

100V o 70V

150 Watts x 2

25V

120 Watts

Respuesta en Frecuencia

Salidas Directas (+0/-2dB)

50Hz - 50kHz

Salidas Aisladas (+0/-2dB)

50Hz - 16kHz

Distorsión Armónica Total

<0,05

Sensibilidad (salida completa)

1,02V

Ganancia de Voltaje

28dB

Impedancia de Entrada

Balanceada/Desbalanceada

20k/10k ohm

Factor Damping

>200 (direct output)

Relación S/R

Menor a 100dB debajo de la salida medida (20Hz-20kHz)

Circuitos de Protección

Protección de offset de voltaje de salida

Protección de disipador de calor de sobrecalentamiento

Protección de sobrecalentamiento de transformador

Protección de corto de carga

Protección de encendido/apagado

Controles

Panel Frontal

Botón de encendido

Panel de Dorso

Controles de Ganancia Ch1 & Ch2 (41 clicks); 

selector Paralelo/Estéreo/Bridge

Conectores

Entrada

XLR jack x2, Bornes de seguridad x1

Salida

Bornes de seguridad x2; binding post resistente

Cooling

Un ventilador de velocidad dual

Indicadores

Clip: Rojo

Señal: Verde

Protección: Amarillo

Encendido: Rojo

Dimensiones (AlxAnxP)

132 x 480 x 428mm (5,2” x 19” x 16,9”)

Peso Neto

20,2 Kg (44,5 lbs)

Summary of Contents for SR703

Page 1: ...User s Manual Manual del Usuario Contractor Power Amplifier Amplificador de Potencia Para Contratista SR703...

Page 2: ...CIONES 10 ACERCA DE ESTE MANUAL 10 PANEL FRONTAL 10 PANEL POSTERIOR 11 CONEXIONES DE ENTRADA 12 CONEXIONES DE SALIDA 12 ESPECIFICACIONES 14 DIMENSIONS DIMENSIONES 15 Asystems reserves the right to alt...

Page 3: ...paratus during lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power su...

Page 4: ...er is in place over the output terminals and do not touch any exposed speaker wiring while the amplifier is operating ABOUT THIS MANUAL Please be reminded that a power amplifier is a high current high...

Page 5: ...ther SR or other amplifier 9 Stereo Parallel Bridge Switch In Stereo operation two separate signals are treated separately by channels 1 and 2 of the amplifiers In Parallel operation one signal is tre...

Page 6: ...f before you change any output connections Loose screw terminals insert wire connectors under screws Tighten screw terminals Direct Low Impedance Output connection for SR703 bridge mono mode Output co...

Page 7: ...refer to the Rear Panel section on page 5 Low Impedance and Distributed Speakers If your application calls for connection of an 8 ohm speaker and a distributed line to the same amplifier channel the S...

Page 8: ...mpedance Balanced Unbalanced 20k 10k ohm Damping Factor 200 direct output S N Ratio Less than 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat sink overhea...

Page 9: ...9 SR703 AMPLIFICADOR DE POTENCIA PARA CONTRATISTA Espa ol...

Page 10: ...os a la salida Para evitar descargas el ctricas aseg rate de que la cubierta este encima de las terminales de salida y no toques ning n cable de altavoz que este expuesto mientras el amplificador este...

Page 11: ...amplificador 9 Selector Est reo Paralelo Bridge En operaci n est reo dos se ales separadas ser n transmitidas por los canales 1 y 2 de los amplificadores En operaci n en Paralelo una se al es tratada...

Page 12: ...ado antes de cambiar cualquier conexi n de salida Liberal los tornillos de las terminales inserta las conexiones de los cables debajo de los tornillos Aprieta firmemente las terminales de los tornillo...

Page 13: ...or favor refi rete a la descripci n previa del Panel Trasero Altavoces Distribuidos y de Baja Impedancia en los Amplificadores SR703 SI tus aplicaciones necesitan la conexi n de altavoces de 8 ohm y u...

Page 14: ...esbalanceada 20k 10k ohm Factor Damping 200 direct output Relaci n S R Menor a 100dB debajo de la salida medida 20Hz 20kHz Circuitos de Protecci n Protecci n de offset de voltaje de salida Protecci n...

Page 15: ...15 SR703 CONTRACTOR AMPLIFIER Appendix DIMENSIONS DIMENSIONES Measurements are shown in mm inches Todas las medidas est n mostradas en mm pulgadas 132 5 2 480 19...

Page 16: ...www asystems sys com...

Reviews: