background image

8

SR703 | SR707 CONTRACTOR AMPLIFIER

English

SR703

SR707

Direct Power Out

8 ohm

120 Watts x 2

240 Watts x 2

4 ohm

200 Watts x 2

400 Watts x 2

2 ohm,1kHz,1%THD

300 Watts x 2

550 Watts x 2

Bridged mono 8 ohm,1kHz,1%THD

420 Watts

850 Watts

Bridged mono 4 ohm,1kHz,1%THD

540 Watts

1100 Watts

Isolated Constant Voltage Out

200V or 140V Bridge

300 Watts

700 Watts

100V or 70V

150 Watts x 2

350 Watts x 2

25V

120 Watts x 2

280 Watts x 2

Frequency Response

Direct Outputs (+0/-2dB)

50Hz - 50kHz

50Hz - 50kHz

Isolated Outputs (+0/-2dB)

50Hz - 16kHz

50Hz - 16kHz

Total Harmonic Distortion

<0�05

<0�05

Sensitivity (for full output)

1�02V

1�02V

Voltage Gain

28dB

28dB

Input Impedance

Balanced/Unbalanced

20k/10k ohm

20k/10k ohm

Damping Factor

>200 (direct output)

>200 (direct output)

S/N Ratio

Less than 100dB below rated output

(20Hz - 20kHz)

Less than 100dB below rated output

(20Hz - 20kHz)

Protection Circuits

Output offset voitage protection

Heat sink overheat protection

Transformer overheat protection

Load shorting protection

Power on/off protection

Output offset voitage protection

Heat sink overheat protection

Transformer overheat protection

Load shorting protection

Power on/off protection

Controls

Front Panel

Power Switch

Power Switch

Rear Panel

Ch 1 & Ch 2 gain controls (41 click); 

Parallel/Stereo/Bridge Switch

Ch 1 & Ch 2 gain controls (41 click); 

Parallel/Stereo/Bridge Switch

Connectors

Input

XLR Jack x 2, Barrier Strip x 1

XLR Jack x 2, Barrier Strip x 1

Output

Covered Barrier Strip x 2; 

Heavy-Duty Binding Post

Covered Barrier Strip x 2; 

Heavy-Duty Binding Post

Cooling

One dual speed fan

One dual speed fan

Indicators

Clip: Red

Signal: Green

Protect: Yellow

Power: Red

Clip: Red

Signal: Green

Protect: Yellow

Power: Red

Dimensions (HxWxD)

132 x 480 x 395mm (5�2” x 19” x 15�6”)

132 x 480 x 395mm (5�2” x 19” x 15�6”)

Net Weight

20 Kg (44�1 lbs)

24�7 Kg (54�6 lbs)

SPECIFICATIONS

Summary of Contents for SR707

Page 1: ...User s Manual Manual del Usuario Contractor Power Amplifier Amplificador de Potencia Para Contratistas SR703 SR707...

Page 2: ...CAUCIONES 10 ACERCA DE ESTE MANUAL 10 PANEL FRONTAL 10 PANEL POSTERIOR 11 CONEXIONES DE ENTRADA 12 CONEXIONES DE SALIDA 12 ESPECIFICACIONES 14 DIMENSIONS DIMENSIONES 15 Asystems reserves the right to...

Page 3: ...apparatus during lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power...

Page 4: ...e cover is in place over the output terminals and do not touch any exposed speaker wiring while the amplifier is operating ABOUT THIS MANUAL Please be reminded that a power amplifier is a high current...

Page 5: ...another SR or other amplifier 9 Stereo Parallel Bridge Switch In Stereo operation two separate signals are treated separately by channels 1 and 2 of the amplifiers In Parallel operation one signal is...

Page 6: ...he amplifier is turned off before you change any output connections Loose screw terminals insert wire connectors under screws Tighten screw terminals Direct Low Impedance Output connection bridge mono...

Page 7: ...er to the Rear Panel section on page 5 Low Impedance and Distributed Speakers If your application calls for connection of an 8 ohm speaker and a distributed line to the same amplifier channel the SR70...

Page 8: ...n 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat sink overheat protection Transformer overheat protection Load shorting protection Power on off protectio...

Page 9: ...9 SR703 SR707 AMPLIFICADOR DE POTENCIA PARA CONTRATISTAS Espa ol...

Page 10: ...s a la salida Para evitar descargas el ctricas aseg rese de que la cubierta este encima de los terminales de salida y no toque ning n cable de altavoz que este expuesto mientras el amplificador este o...

Page 11: ...SR o a cualquier otro amplificador 9 Selector Est reo Paralelo Bridge En operaci n est reo dos se ales separadas ser n transmitidas por los canales 1 y 2 de los amplificadores En operaci n en Paralelo...

Page 12: ...or este apagado antes de cambiar cualquier conexi n de salida Liberal los tornillos de los terminales inserte las conexiones de los cables debajo de los tornillos Apriete firmemente los tornillos de l...

Page 13: ...er n ajustarse independientemente Por favor referirse a la descripci n previa del Panel Trasero Altavoces Distribuidos y de Baja Impedancia en los Amplificadores SR703 y SR707 Si sus aplicaciones nece...

Page 14: ...Impedancia de Entrada Balanceada Desbalanceada 20k 10k ohm 20k 10k ohm Factor de Amortiguaci n Damping 200 entrada directa 200 entrada directa Relaci n S R Menor a 100dB debajo de la salida medida 20...

Page 15: ...15 SR703 SR707 CONTRACTOR AMPLIFIER Appendix DIMENSIONS DIMENSIONES Measurements are shown in mm inches Todas las medidas est n mostradas en mm pulgadas 132 5 2 480 19...

Page 16: ...www asystems sys com...