Operating instructions
a-TroniX inverter AX series, 1ph
A NOTICE
2. In off-grid operation, ensure the power of EPS loads
The inverter is set to the EPS wiring mode “External” by default, it can be
set to “Internal” via the display setting “Menu - Setting - Function - Bypass
Relay”.
A NOTICE
Using internal EPS wiring:
is less than the maximum EPS power of the inverter.
1. During mains operation, ensure that the power of the EPS loads is lower
EPS mode can be achieved by two different types of wiring. On the one hand, the
internal bypass can be used to connect the home emergency call loads to the EPS
connection of the inverter. Another is to use an external contactor to wire the EPS
loads to the contactor itself (the external contactor must be purchased separately).
is than the maximum bypass power of the inverter.
atx009de0823
Page 33
6.6 EPS connection
A. EPS wiring
3. We recommend not connecting inductive loads to the EPS port.
Machine Translated by Google