www.a-ts.cn A-TS Technology RT10
37
4 Running
4.1 Set motor type
1)
Power on
After the power is up, the PWR indicator is lit. If an alarm occurs,
please check the wiring.
2)
Check the motor type
Check the parameter PA1 value, and find the motor type
corresponding to this parameter in the Motor selection guide. Check
whether the motor type connected to the drive is in accord with the one
above. If they are the same, go to the next step. If not the same, please
modify the motor type.
INSTRUCTIONS
RT10 series servo drive supports standard motor and user defined
motor. If it is standard motor, set the motor type code according to the
motor adaptation table (in the motor selection guide). If it is user-defined
motor, need to set the parameters of motor manually.
3)
Modify the motor type code
Follow the steps below to modify the motor type
Change the
PA0 ‘parameter password’ to 385, and press the Enter key
to save.
Set
in
as the motor manufacturer type, and
press the Enter key to save.
Find the motor type code in the Motor Selection Guide, and set the
PA1 parameter Motor type to this type code. If there is no type code