background image

5/96                                                                                            FORM #262

OPERATING INSTRUCTIONS

MODEL DM-2A

POCKET-PRO

®

DIGITAL MULTIMETER

ONE YEAR LIMITED WARRANTY

A.W. Sperry Instruments, Inc., warrants that this A.W.
Sperry instrument has been carefully tested, inspect-
ed, and warranted for one (1) year from the date of
purchase by the original end user, provided the instru-
ment has not been misused, damaged due to
negligence, neglect or unauthorized repair, abused or
used contrary to the operating instructions.
Instruments and proof of purchase in the form of a
legible copy or original of the sales receipt clearly
identifying the distributor, model number and date of
purchase must be returned to A.W. Sperry
Instruments, Inc., Attention:  Customer Service Center,
245 Marcus Boulevard, Hauppauge, New York 11788,
postage prepaid for examination and verification of
manufacturing defect under warranty.  A.W. Sperry
Instruments, Inc., shall be the sole judge of such
defect.  The liability of A.W. Sperry Instruments, Inc.,
shall be limited to the repair or replacement at its sole
option of any defective product.

1) INTRODUCTION

The DM-2A is an innovative concept in digital multimeter
design. It is a miniature ultra-slim DMM which combines
the measurement capabilities of a 16 range, 4 function
digital instrument with the handiness and simplicity of a
pocket calculator. The DM-2A features the latest develop-
ments in high-technology construction and design. All the
features of larger sized DMM’s are to be found in the
DM-2A. Autoranging, overload protection on all ranges,
auto polarity, audible/visual continuity indication, sturdy
ABS plastic case and much more. The DM-2A is
extremely easy to use. Two thumb operated switches

control all functions. The test leads are built into the
instrument and cannot be removed. They are always
there when you need them. A handy “booklet style” carry-
ing case which hold the instrument, test leads and
operating instructions is included, and allows the DM-2A
to be carried easily in your shirt pocket.

2) FEATURES

UL LISTED

…to both US and Canadian standards 

16 RANGES, 4 FUNCTIONS
LIMITED ONE YEAR WARRANTY.
AUTO RANGING /MANUAL RANGING
SIMPLE OPERATION
CONTINUITY BUZZER
RANGE HOLD BUTTON
BUILT IN TEST LEADS

3) SPECIFICATIONS

Display: 

3

1

2

digit liquid crystal display (LCD), 

maximum reading 1999 with automatic 
sign and function annunciators.

Range 

Selection:

Autoranging/Manual ranging.

Polarity:

Automatic (-) negative polarity 
indication.

Overrange: 

Most significant digit blinks

Low Battery 

Indication: 

The “B” is displayed when the battery 
voltage drops below the operating 
level.

Measurement 

Rate: 

2.5 times per second, nominal.

Operating 

Environment:

0° to 40°C (32° to 104°F) Max RH 
80% to 31°C, decreasing linearly to 
50% RH at 40°C.

Storage 

Temperature:

-20°C to 60°C (-4° to 140°F) at 
80% relative humidity.

Power: 

Two 1.5V button-type batteries 
(IEC # LR-44, NEDA #1166A). 
Sperry Part #B-6

Power 

Consumption:

5mW typical.

Dimensions:

4

3

8

"H x 2

1

4

"W x

3

8

"D

(111.5mm H x 56mm W x 10.5mm D)

Weight: 

Approx. 3.0 oz (86g) including 
batteries and case.

Instrument complies with insulation category (over volt-
age category II). Pollution degree 2 in accordance with
IEC-1010-1 Indoor use. If the equipment is used in a
manner not specified, the protection provided by the
equipment may be impaired.

4) PACKAGING

The DM-2A comes complete with two B-6 batteries, C-77
carrying case and form # 262 operating instructions.

DOUBLE INSULATION

WARNING: 

TO AVOID ELECTRIC SHOCK DISCONNECT

MEASURING TERMINALS BEFORE REMOVING BACK COVER.

AVIS: 

POUR EVITER LE CHOC ELECTRIQUE DEBRANCHER

LES BORNES DE MEAURE AVANT D’ENLEVER LE CAPOTAGE
ARRIERE.

WHEN SERVICING, USE ONLY SPECIFIED 
“REPLACEMENT PARTS” OR EQUIVALENT.

5) SAFETY PRECAUTIONS

The following safety precautions must be observed to
insure maximum personal safety during the operation at
this meter.

1. Read these operating instructions thoroughly and 

completely before operating your Pocket Pro. Pay 
particular attention to WARNINGS which will inform 
you of potentially dangerous procedures. The 
instructions in these warnings must be followed.

2. Always inspect your meter, test leads and 

accessories for any sign of damage or abnormality 
before every use. If any abnormal conditions exists 
(e.g. broken test leads, cracked cases, display not 
reading, etc.), do not attempt to take any 
measurements. Refer to Return for Repair section.

3. Never ground yourself when taking electrical 

measurements. Do not touch exposed metal pipes, 
outlets, fixtures, etc. which might be at ground 
potential. Keep your body isolated from ground by 
using dry clothing, rubber shoes, rubber mats, or any 
approved insulating material.

4. To avoid electric shock use CAUTION when working 

with voltages above 40Vdc or 20Vac. Such voltages 
pose a shock hazard.

5. Never exceed the maximum allowable input value of 

any function when taking measurement. Refer to the 
chart above for maximum inputs

6. Never touch exposed wiring, connections or any live 

circuit when attempting to take measurements.

7. Do not attempt to operate this instrument in an 

explosive atmosphere (i.e in the presence of 
flammable gases or fumes, vapor or dust).

8. When testing for the presence of voltage make sure 

the voltage function is operating properly by reading 
a known voltage in that function before assuming 
that a zero reading indicates a no-voltage condition. 

Always Think Safety, Act Safely

6) OPERATION

Before taking any measurements, read the Safety
Information Section. Always examine the instrument for
damage, contamination (excessive dirt, grease, etc.) and
defects. Examine the test leads for cracked or frayed
insulation. If any abnormal conditions exist do not attempt
to make any measurements. To clean, wipe with a clean
dry cloth.

Autoranging

The meter defaults to autorange when you turn it on. In
autorange, the meter selects the range automatically.

Manually Selecting a Range

The meter also has a manual range mode. In manual
range, you select and lock the meter in a range. To man-
ually select a range:

Press [RANGE HOLD] button to hold the selected range.
Subsequently pressing the [RANGE HOLD] button will
select each range in sequence from the lowest to the
highest range. Hold the button for 2 seconds to return to
the Autorange Mode.

Data Hold Feature

Press [DATA HOLD] button to toggle in and out of the
Data Hold mode. In the data hold mode, the annunciator
is displayed and the last reading is held on the display.
Press [DATA HOLD] button again to release the hold and
current readings are once again displayed.

Measuring Voltage

1. Set the Function Switch to “VOLT” position.

2. Select the Mode Switch to desired AC voltage range 

or DC voltage range.

WARNING

To avoid possible electric shock and/or instrument
damage, do not attempt to take any voltage measure-
ments if the voltage is above 450Vdc/ac is the
maximum voltage that this meter is designed to mea-
sure. the black (-) test lead potential should not
exceed 450Vdc/ac measured to earth ground.

3. Apply the test lead probe tips to the two points 

where a voltage reading is to be taken. The meter 
will automatically select the proper range and display 
the reading.

4. When measurements are completed, disconnect the 

test leads from the circuit under test.

Measuring Resistance

1. Set the Function Switch to “

/ •

)

)

)

” position.

2. Select the Mode Switch to “

” position.

3. Completely de-energize the circuit or device to be 

measured. Connect the test lead probe tips to the 
device.

4. The meter will automatically select the proper range 

and display the reading.

Note: 

The most significant digit blink indicates an overrange 

condition. This will occur with the test leads open.

Measuring Continuity

1. Set the Function Switch to “

/•

)

)

)

” position.

2. Select the Mode Switch to “•

)

)

)

” position.

3. Connect the test leads to the two points at which 

continuity is to be tested. The buzzer will sound if 
the resistance is approximately 650

± 200

.

WARNING

All resistance and continuity measurements should
be taken on de-energized circuits only to insure safe
and accurate measurements. To avoid possible elec-
trical shock, instrument damage and/or equipment
damage, do not connect the test leads to circuits hav-
ing a potential difference greater than 450Vdc/ac. Do
not connect the test leads to potentials exceeding
450V to earth ground.

7) BATTERY REPLACEMENT

Power is supplied by two button-type batteries (NEDA
1166A, IEC LR-44). “B” appears on the LCD display
when replacement is needed.

WARNING

Before attempting to replace the battery, first discon-
nect the Test Leads from any energized circuit.

1. Disconnect the test leads from any energized circuit.

2. Set the Function Switch to OFF.

3. Remove battery cover screw.

4. Slide off battery cover and change batteries.

5. Replace battery cover and screw.

A.W. SPERRY INSTRUMENTS INC.

The Professional’s Choice

®

Battery Replacement

Battery 
Compartment Cover

Screw

F

u

n

c

ti

o

n

R

a

n

g

e

A

c

c

u

ra

c

y

In

p

u

t

O

v

e

rl

o

a

d

D

C

V

A

C

V

Im

p

e

d

a

n

c

e

P

ro

te

c

ti

o

n

2

0

0

m

V

N

/A

2

V

4

5

0

V

D

C

D

C

&

A

C

2

0

V

±

(2

%

rd

g

(5

0

/6

0

H

z

)

>

1

0

M

o

r

V

o

lt

a

g

e

2

0

0

V

+

2

d

)

±

(4

%

rd

g

4

5

0

V

A

C

rm

s

4

5

0

V

+

5

d

)

(s

in

e

)

2

0

0

2

k

R

e

s

is

ta

n

c

e

2

0

k

±

(2

%

rd

g

+

2

d

)

2

0

0

k

N

/A

4

5

0

V

D

C

2

0

0

0

k

o

r

2

0

M

±

(5

%

rd

g

+

1

0

d

)

4

5

0

V

A

C

rm

s

C

o

n

ti

n

u

it

y

2

k

A

u

d

ib

le

a

n

d

V

is

u

a

l

In

d

ic

a

ti

o

n

a

t

<

6

5

0

±

2

0

0

!

!

5/96                                                                                   Formulario No. 262

INSTRUCCIONES DE MANEJO

MODELO DM-2A

POCKET-PRO

®

MULTIMETRO DIGITAL

GARANTIA LIMITADA DE UN AÑO

A.W. Sperry Instruments, Inc., garantiza que este instrumento A.W.
Sperry ha sido cuidadosamente probado, inspeccionado y garantiza-
do por un (1) año a partir de la fecha de compra por el usuario final
original, a condición de que el instrumento no haya sido usado inde-
bidamente, dañado debido a negligencia, descuido o reparación no
autorizada, abusado o usado en forma contraria a las instrucciones
de manejo. Los instrumentos y la prueba de compra en forma de
una copia u original legible del recibo de venta que identifique clara-
mente el distribuidor, el número de modelo y la fecha de compra,
deben ser devueltos a A.W. Sperry Instruments, Inc., Attention:
Customer Service Center, 245 Marcus Boulevard, Hauppauge, New
York 11798, con franqueo prepago para el examen y verificación del
defecto de fabricación bajo garantía. A.W. Sperry Instruments, Inc.,
será el único juez de dicho defecto. La responsabilidad de A.W.
Sperry Instruments, Inc., se limitará a la reparación o cambio a su
sola opción de cualquier producto defectuoso.

1) INTRODUCCION

El modelo DM-2A es un concepto innovador en el diseño
de multímetros digitales. Es un MMD ultradelgado en
miniatura que combina la capacidad de medición de un
instrumento digital de 16 gamas y 4 funciones con la
practicidad y simplicidad de una calculadora de bolsillo.
El modelo DM-2A presenta los últimos adelantos en con-
strucción y diseño de alta tecnología. Todas las
características de los MMD de tamaño más grande se
encuentran en el modelo DM-2A. Selección automática
de gamas, protección contra sobrecarga en todas las
gamas, autopolaridad, indicación de continuidad audi-
ble/visual, estuche plástico ABS resistente y mucho más.
El modelo DM-2A es sumamente fácil de usar. Dos
selectores accionados con el dedo pulgar controlan todas
las funciones. Los conductores de pruebas están incor-
porados en el instrumento y no se pueden quitar.
Siempre están allí cuando usted los necesita. Se incluye
un práctico estuche estilo “libreta” que contiene el instru-
mento, los conductores de pruebas y las instrucciones de

manejo y permite que usted pueda llevar el DM-2A
fácilmente en el bolsillo de la camisa.

2) CARACTERISTICAS

LISTADO POR LA ASOCIACION DE ASEGURADORES 

(UL)

...según las normas de EE.UU. y Canadá

16 GAMAS, 4 FUNCIONES
GARANTIA LIMITADA DE UN AÑO
SELECCION DE GAMAS AUTOMATICA Y MANUAL
MANEJO SENCILLO
APAGADO AUTOMATICO
ZUMBADOR DE CONTINUIDAD
BOTON DE RETENCION DE GAMA
CONDUCTORES DE PRUEBAS INCORPORADOS

3) ESPECIFICACIONES

Visualizador:

Visualizador de cristal líquido digital 
de 3

1

/

2

(LCD), lectura máxima de 1999 

con señal automática y anunciadores 
de función.

Selección de 

gamas:

Selección de gamas automática y 
manual.

Polaridad:

Indicación de polaridad negativa (-) 
automática.

Sobregama:

El dígito más significativo centellea.

Indicación de

poca pila:

Aparece la “B” cuando el voltaje de la 
pila cae por debajo del nivel de 
operación.

Velocidad 

de medición:

2,5 veces por segundo, nominal.

Ambiente de 

operación:

0° a 40°C (32° a 104°F). Humedad 
relativa máxima de 80% a 31°C, 
disminuyendo linealmente a una 
humedad relativa de 50% a 40°C.

Temperatura de 

almacenamiento:

-20°C a 80°C (-4° a 140°F) a <80% de 
humedad relativa.

Energía:

Dos pilas tipo botón de 1,5V 
(IEC # LR-44, NEDA # 186A). 
Pieza Sperry # B-6

Consumo de 

energía:

5mW normalmente.

Dimensiones:

4

3

/

8

” de altura, 2

1

/

4

” de ancho y 

3

/

4

” de 

profundidad (111,5 mm de altura x 
56 mm de ancho x 10,5 mm de 
profundidad)

Peso:

Aproximadamente 3,0 onzas 
(86 gramos) incluyendo las pilas y el 
estuche.

El instrumento cumple con la categoría de aislación (cat-
egoría de sobrevoltaje II). Grado de contaminación 2 de
conformidad con la IEC-1010-1. Uso en interiores. Si el
equipo se utiliza en una forma no especificada, la protec-
ción suministrada por el equipo puede verse afectada
negativamente.

4) EMPAQUE

El modelo DM-2A incluye dos pilas B-6, un estuche portátil
C-77 e instrucciones de manejo, formulario No. 262.

DOBLE AISLACION

ADVERTENCIA: 

PARA EVITAR CHOQUE ELECTRICO,

DESCONECTE LAS TERMINALES DE MEDICION ANTES DE
QUITAR LA TAPA POSTERIOR.

Cuando servicio, usa soló especifico “partes de 
recambió” o equivalente.

A.W. SPERRY INSTRUMENTS INC.

The Professional’s Choice

®

F

u

n

c

n

G

a

m

a

P

re

c

is

n

Im

p

e

d

a

n

c

ia

P

ro

te

c

c

n

V

C

C

V

C

A

d

e

e

n

tr

a

d

a

co

n

tr

a

so

b

re

ca

r-

g

a

2

0

0

m

V

N

/A

2

V

4

5

0

V

D

C

V

o

lt

a

je

d

e

2

0

V

±

(2

%

rd

g

(5

0

/6

0

H

z

)

>

1

0

M

o

r

C

C

y

C

A

2

0

0

V

+

2

d

)

±

(4

%

rd

g

4

5

0

V

A

C

rm

s

4

5

0

V

+

5

d

)

(s

in

e

)

2

0

0

2

k

R

e

s

is

te

n

c

ia

2

0

k

±

(2

%

rd

g

+

2

d

)

2

0

0

k

N

/A

4

5

0

V

D

C

2

0

0

0

k

o

r

2

0

M

±

(5

%

rd

g

+

1

0

d

)

4

5

0

V

A

C

rm

s

C

o

n

ti

n

u

id

a

d

2

k

In

d

ic

a

c

n

a

u

d

ib

le

y

v

is

u

a

l

!

!

Summary of Contents for DM-2A POCKET-PRO

Page 1: ...262 OPERATING INSTRUCTIONS MODEL DM 2A POCKET PRO DIGITAL MULTIMETER A S e p m n u In le id p In 2 p m In d sh o 1 The des the digi poc me fea DM aut ABS extr A W SPERRY INSTRUMENTS INC The Professional s Choice ...

Page 2: ... warranty A W Sperry Instruments Inc shall be the sole judge of such defect The liability of A W Sperry Instruments Inc shall be limited to the repair or replacement at its sole option of any defective product 1 INTRODUCTION The DM 2A is an innovative concept in digital multimeter design It is a miniature ultra slim DMM which combines the measurement capabilities of a 16 range 4 function digital i...

Page 3: ...TIONS LIMITED ONE YEAR WARRANTY AUTO RANGING MANUAL RANGING SIMPLE OPERATION CONTINUITY BUZZER RANGE HOLD BUTTON BUILT IN TEST LEADS 3 SPECIFICATIONS Display 31 2 digit liquid crystal display LCD maximum reading 1999 with automatic sign and function annunciators Range Selection Autoranging Manual ranging Polarity Automatic negative polarity indication Overrange Most significant digit blinks Low Ba...

Page 4: ... insulation category over volt age category II Pollution degree 2 in accordance with IEC 1010 1 Indoor use If the equipment is used in a manner not specified the protection provided by the equipment may be impaired 4 PACKAGING The DM 2A comes complete with two B 6 batteries C 77 carrying case and form 262 operating instructions DOUBLE INSULATION WARNING TO AVOID ELECTRIC SHOCK DISCONNECT MEASURING...

Page 5: ...ACV Impedance Protection 200mV N A 2V 450VDC DC AC 20V 2 rdg 50 60Hz 10MΩ or Voltage 200V 2d 4 rdg 450VAC rms 450V 5d sine 200Ω 2kΩ Resistance 20kΩ 2 rdg 2d 200kΩ N A 450VDC 2000kΩ or 20MΩ 5 rdg 10d 450VAC rms Continuity 2kΩ Audible and Visual Indication at 650Ω 200Ω ...

Page 6: ... etc do not attempt to take any measurements Refer to Return for Repair section 3 Never ground yourself when taking electrical measurements Do not touch exposed metal pipes outlets fixtures etc which might be at ground potential Keep your body isolated from ground by using dry clothing rubber shoes rubber mats or any approved insulating material 4 To avoid electric shock use CAUTION when working w...

Page 7: ...s Examine the test leads for cracked or frayed insulation If any abnormal conditions exist do not attempt to make any measurements To clean wipe with a clean dry cloth Autoranging The meter defaults to autorange when you turn it on In autorange the meter selects the range automatically Manually Selecting a Range The meter also has a manual range mode In manual range you select and lock the meter i...

Page 8: ...nd or instrument damage do not attempt to take any voltage measure ments if the voltage is above 450Vdc ac is the maximum voltage that this meter is designed to mea sure the black test lead potential should not exceed 450Vdc ac measured to earth ground 3 Apply the test lead probe tips to the two points where a voltage reading is to be taken The meter will automatically select the proper range and ...

Page 9: ...de Switch to position 3 Connect the test leads to the two points at which continuity is to be tested The buzzer will sound if the resistance is approximately 650Ω 200Ω WARNING All resistance and continuity measurements should be taken on de energized circuits only to insure safe and accurate measurements To avoid possible elec trical shock instrument damage and or equipment damage do not connect t...

Page 10: ...RNING Before attempting to replace the battery first discon nect the Test Leads from any energized circuit 1 Disconnect the test leads from any energized circuit 2 Set the Function Switch to OFF 3 Remove battery cover screw 4 Slide off battery cover and change batteries 5 Replace battery cover and screw Battery Replacement Battery Compartment Cover Screw ...

Reviews: