9
To turn the unit off:
• For Ambient Air:
• Turn off the ozone switch.
• Wait 10 seconds before continuing.
• Turn off the air compressor switch.
• For Oxygen Air:
• Turn off the ozone switch
• Wait 10 seconds before continuing.
• Turn off the oxygen source.
Tube Connection and Start Up
An oxygen tank or oxygen generator should be used when pure ozone needed.
Using Oxygen Bottle/Tank:
• Connect oxygen bottle/tank to ozone generator (Oxygen In Port).
• Connect MP unit (Ozone Out Port) to venturi injector.
• Install a check valve 10 inches after ozone outlet tube fitting. This can be done by
cutting a tube ten inches after ozone outlet fitting.
• Connect both ends of cut tubes to the check valve. Please direct the arrow on the check
valve toward venturi injector.
• Set tank gas flow meter at 1-4 liters per minute and 3 PSI maximum.
• First, open the oxygen valve then only turn on the main ozone power switch on the front
panel of the MP unit (internal air compressor switch stays OFF). The ozone light and fan
should turn on.
• Increase power to the cells by turning the ozone concentration knob clockwise. Please
remember to make a full rotation clockwise.
• Prior to shutting off the feed gas to the unit, turn off the switch and allow the unit to
purge for about 1 minute.
• Then, turn the flow of oxygen gas off.
NOTE:
Do not turn the air pump switch ON when using oxygen generator, oxygen bottle or tank.
Using Oxygen Generator:
• Connect oxygen generator (Oxygen Out Port) to ozone generator (
O
2
In Port).
• Connect MP unit (Ozone Out Port) to the venturi injector.
• Install a check valve 10 inches after ozone outlet tube fitting. This can be done by
cutting a tube ten inches after ozone outlet fitting.
• Connect both ends of cut tubes to the check valve.