UL/cUL RESIDENTIAL FIRE & BURGLARY INSTALLATIONS
This product has been tested and found in compliance with the following standards: UL1023 Household Burglar-
Alarm System Units, UL985 Household Fire Warning System Units, ULC-S545 Residential Fire Warning Systems
Control Units and ORD-C1023 Household Burglar Alarm System Units. For ULC Installations refer to the Standard
for the Installation of Residential Fire Warning Systems, CAN/ULC-S540:
- Use only the compatible power supply referenced in this Installation Manual. 24 h standby power must be
provided for fire applications and 4h for burglary only applications (AC trouble must be transmitted to SRC).
- Priority of signals on the Panel is set as Fire, CO, Burg, Panic, Aux and then Flood.
- Use at least one compatible listed Smoke Detector for Fire Installations.
- The entry delay shall not exceed 45 seconds
- The exit delay shall not exceed 60 seconds
- The control panel supports the Temporal 3 pattern for fire alarm notification
- Test transmission cycle shall be set for 7 days transmission for Residential Fire applications, or 30 days for
Residential Burglary only applications.
Note
:
For ULC Residential Fire installations set for daily test transmission, Wireless Supervision window shall be set
to 4 hours for Residential Fire Installations. Wireless Supervision window shall be set to 24 hours for Residential
Burglary Installations only. RF Jam detection shall be enabled.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
OF
166
177
LEGAL
Summary of Contents for Qolsys IQ Panel 2
Page 8: ...INSTALLING THE PANEL...
Page 13: ...USER INTERFACE...
Page 17: ...PROGRAMMING...
Page 52: ...SECURITY SENSORS...
Page 84: ...WI FI DEVICES...
Page 91: ...Z WAVE DEVICES...
Page 102: ...BLUETOOTH DEVICES...
Page 110: ...SYSTEM TESTS...
Page 135: ...CUSTOMIZATION...
Page 148: ...MAINTENANCE...
Page 154: ...TROUBLESHOOTING...
Page 164: ...LEGAL...
Page 172: ...SPECIFICATIONS...