Chapter 3 – Gateway Setup and Configuration
29
IO
T G
at
eway
S
ystem
SRG
-IMX8
P
COM P2 (CN5):
RS232 mode GPIO control:
echo 0 > /sys/class/gpio/gpio85/value
echo 1 > /sys/class/gpio/gpio86/value
echo 0 > /sys/class/gpio/gpio87/value
echo 1 > /sys/class/gpio/gpio12/value
RS485 mode GPIO control:
echo 1 > /sys/class/gpio/gpio85/value
echo 0 > /sys/class/gpio/gpio86/value
echo 1 > /sys/class/gpio/gpio87/value
echo 0 > /sys/class/gpio/gpio12/value
RS422 mode GPIO control:
echo 0 > /sys/class/gpio/gpio85/value
echo 0 > /sys/class/gpio/gpio86/value
echo 0 > /sys/class/gpio/gpio87/value
echo 0 > /sys/class/gpio/gpio12/value