DELIVERY CHECKLIST  

 

 

Before starting installation, check that you have the following parts;  

 

 

1.

 

Catering Water Boiler  

2.

 

Drip-tray  

3.

 

Drip-tray drain fitting (Optional - for connecting front drip-tray to a permanent waste/drain)  

4.

 

Tapered rubber bung (Optional - for blanking off front outlet if rear-overflow outlet is preferred)    

5.

 

White mains water inlet hose (3/4” BSP connection) 6.

 

User instructions  

  

TECHNICAL SPECIFICATION  

 

 

 

 

AA1000/TF 

 

 

Immediate Draw-off: 

 

10 Litres  

 

Output per hour: 

 

31 Litres 

 

Width: 

 

240 mm 

 

 

Depth inc. drip-tray: 

 

522 mm 

 

 

Height: 

 

545 mm 

 

 

Power Rating: 

 

3.0 Kw 

 

 

Weight-Empty: 

 

12.3 KG 

 

 

Weight-Full: 

 

26.5 KG 

 

 

Water Inlet Pressure: 

 

2 to 7 Bar 

 

 

 

 

  
 
 
 
 
 
 
 
 

Summary of Contents for Touch-Free AA1000/TF

Page 1: ...000 TF Auto Fill Water Boiler with TOUCH FREE Dispense INSTALLATION AND USER INSTRUCTIONS AA First Cedar House Grange Farm Long Lane Shaw Newbury Berkshire RG14 2TF Tel 01635 202489 E enquiries aafirs...

Page 2: ...INFORMATION DELIVERY CHECK LIST 2 TECHNICAL SPECIFICATION 3 INSTALLATION 3 OPERATION 4 OPTIONAL TIMED DISPENSE with Top up facility 4 REGULAR DAILY USE 5 CLEANING 6 MAINTENANCE SPARES SERVICE INFORMAT...

Page 3: ...ers that the appliance contains and dispenses near boiling water Care should be taken to avoid potential injury from burns and scalding whilst operating this appliance In line with Health and Safety r...

Page 4: ...AA First for further information or local authority for details of your nearest designated collection point DELIVERY CHECKLIST Before starting installation check that you have the following parts 1 C...

Page 5: ...ity and is designed to handle small spillages and drips only Wherever possible we strongly recommend that it is connected to a permanent waste outlet using the fitting kit provided If preferred and as...

Page 6: ...t the correct temperature IMPORTANT NOTE In normal daily use the boiler may be used as soon as the READY message is displayed but on first install wait 15 minutes before starting to use The boiler is...

Page 7: ...ve the measured dispense amount this saves the setting and puts the boiler into standby mode To continue switch boiler back on by pressing the ON OFF button again The boiler will now dispense the meas...

Page 8: ...d twist to pop off the outer lid Remove tank lid four fixing screws Lift out the evaporation plates inside of tank Remember order of removal Remove as much scale as possible by hand Any scale which is...

Page 9: ...probe has scaled up De scale level sensors N O T R E A D Y TH RED SCREEN FLASHING WITH WARNING TRIANGLES Over boiled due to excessive scale in tank Faulty Element Thermistor disconnected wires cut or...