2.   INSTALLATION

2.1   Primary Gas Connections

Prior to connecting gas lines inspect all parts of the piping system includ-
ing ferrules and fittings for dust or other contaminants. Be sure to observe
the direction of gas flow as indicated by the arrow on the front of the
meter when connecting the gas system to be monitored.

Insert tubing into the compression fittings until the ends of the properly
sized tubing home flush against the shoulders of the fittings.
Compression fittings are to be tightened according to the manufacturer's
instructions to one and one quarter turns. Avoid over tightening which will
seriously damage fittings.

SMV Motorized Valves  are supplied with standard 3/8 inch (SMV-20),  1/2
inch (SMV-30), or 3/4 inch (SMV-40) inlet and outlet compression fittings.

Using a Helium Leak Detector or other equivalent method perform a thor-
ough leak test of the entire system. (All SMV's are checked prior to ship-
ment for leakage within stated limits. See specifications in this manual.)

2.2   Electrical Connections

The motorized valve requires a +12VDC or optional 24VDC supply with
a minimum current rating of 800 mA. Operating power and valve control
signals are supplied via the 9-pin "D" connector located at the side of the
valve. For normal operating the motorized valve requires at least two con-
trol signals:

l

Direction (12V CMOS logic level, pin 8 on the 9-pin "D" connector)

l

Speed (0-2.5 VDC analog signal, pin 4 on the 9-pin "D" connector)

When direction is LOW (GND) valve goes down (closes), when direction
is HIGH  valve goes up (opens). The "speed" voltage on pin 4 determines
how quickly the valve will operate. The signal amplitude for "speed" con-
trol signal must remain within the limits of 0 to +2.5 VDC. 

It may be necessary to override "direction" and "speed" signals with a
preset (2.75 VDC) speed control signal. This can be accomplished with
valve CLOSE and PURGE control signals (open collector NPN compati-
ble). In order to CLOSE valve pin 3 on the 9-pin "D" connector has to be
connected to GND (pin 2). A GREEN light on the top of the valve will indi-
cate a CLOSE valve condition. In order to PURGE valve pin 7 on the 9-
pin "D" connector has to be connected to GND (pin 2).  A RED light on

2

Summary of Contents for SMV

Page 1: ...e Technical Data Sheet No TD0305M Rev F Date of Issue April 2021 aalborg 20 CORPORATE DRIVE ORANGEBURG NY 10962 PHONE 845 770 3000 FAX 845 770 3010 e mail info aalborg com toll free in usa or canada 1...

Page 2: ...rt applications CAUTION K Factors at best are only an approximation K Factors should not be used in applications that require accuracy better than 5 to 10 Aalborg reserves the right to make changes to...

Page 3: ...Gas Connections 2 2 Electrical Connections 3 SPECIFICATIONS 3 1 CE Compliance 4 OPERATING INSTRUCTIONS 4 1 Preparation and Warm Up 4 2 Valve OFF Control Open Collector NPN Compatible 4 3 Valve Purge...

Page 4: ...se report any shortages promptly 1 3 Returning Merchandise for Repair Please contact the customer service representative of your distributor or Aalborg if you purchased your Motorized Valve directly a...

Page 5: ...2 2 Electrical Connections The motorized valve requires a 12VDC or optional 24VDC supply with a minimum current rating of 800 mA Operating power and valve control signals are supplied via the 9 pin D...

Page 6: ...ector may or may not coincide with the numbering sequence shown in our pin configuration table above It is imperative that you match the appropriate wires in accordance with the correct sequence regar...

Page 7: ...ssion and 3 4 FNPT ELECTRICAL CONNECTIONS 9 pin D connector located at the side of the valve POWER INPUT 12Vdc 800mA standard or optional 24Vdc 600mA Power input is protected by 1600mA resetable fuse...

Page 8: ...borg makes no expressed or implied guarantees of corrosion resist ance of Motorized Valves as pertains to different flow media reacting with components of valves It is the customers sole responsibilit...

Page 9: ...Fitting Stainless Steel 3 8 SMV40 A Aluminum 1000 2119 28 7 4 1 735 3 4 FNPT 1 2 SMV40 S 316 Stainless Steel PTFE 1000 2119 28 7 4 1 735 3 4 FNPT 1 2 6 TABLE I FLOW CONFIGURATIONS 4 OPERATING INSTRUCT...

Page 10: ...ontrol valve off and on again Closing of the valve without changing the speed and direction control signals can be accomplished by connecting pin 3 of the 9 pin D connector to COMMON power ground The...

Page 11: ...rations It was carefully packed to prevent damage during shipment Should you feel that the instrument is not functioning properly please check for the fol lowing common conditions first Are all cables...

Page 12: ...rol signals inadequate gas pressure apply appropriate gas pressure cable or connector malfunction check cables and all connections or replace valve out of adjustment return to factory for repair repla...

Page 13: ...10 APPENDIX 1 SMV MOTORIZED VALVE SMV20 control valve 6 425 163 mm 1 125 29 mm 3 8 compression fitting 3 000 76 2 mm 5 16 131 mm depth 2 000 50 8mm...

Page 14: ...11 SMV30 control valve 6 800 173 mm 3 000 76 2 mm 1 2 compression fittings 1 500 38 1 mm depth 2 00 50 8 mm SMV40 control valve 6 800 173 mm 3 000 76 2 mm 3 4 FNPT 1 500 38 1 mm depth 2 000 50 8 mm...

Page 15: ...he customer that only operators with basic knowledge of the equipment and its limi tations are permitted to control and operate the equipment covered by this warranty Anything to the contrary will aut...

Reviews: