4. Operation and maintenance
The module is to be connected to EEM MOT 01
FE…
displays by RS485
(line RS0) and AUX AVS 01 module (line RS1) and diagnostic connector
(line RS03).
4.1. Measured signals
The type and value range of signals measures by the Module are listed in
Table 2.
Tab. 2 Signals processed by EMS DAQ R02.01 Module
No.
Parameter
Measurement range
Accuracy
1
Engine speed
0
6500 rpm
± 10 rpm
2
Rotor speed
0
500 rpm
± 1 rpm
3
Inlet air temperature
0,3
4 bar abs.
± 0,1 bar
4
Oil pressure
0
10 bar
± 0,1 bar
5
Oil temperature
-20
200°C
± 2°C
6
Cylinder head temperature
-20
200°C
± 2°C
7
Exhaust gases temperature
-50
950°C
± 5°C
8
Inlet air temperature
-20
200°C
± 2°C
9
Fuel level
10
120 l
± 1 l
10
Trim pitch and roll
0
10 V
± 0,1V
11
Flight time
± 1 s
12
Total engine running time (HOOBS)
± 1 min
4.2. Signal analysis
The EMS DAQ R02.01 Module analyses and records instances and duration
of the signals’ exceeding threshold values for selected engine par
ameters