Operators and Maintenance Manual
Measuring module
EMS DAQ R02.01
Page
15/18
Copyright:
Auto & Aero Technologies Sp. z o.o.
Mazowiecka 10/5, 20-723 Lublin, Poland
■
email: info@aatech.pl
■
www.aatech.pl
5.4. Troubleshooting
a)
If information is not displayed on some of the monitors (
type FE…
)
when power is applied (Fig. 8), check connection inside
measurement module. Check:
power connection; ensure that your power supply is
capable of supplying at least 8 volts, and no more than
30 V.
data bus connection (RS0);
Fig. 3. Indication of no connection to measurement module
a)
If the system does not react to brightness adjustment, check
connection with AUX AVS 01 (RS1);
b)
In the case of the
module’s
failure or malfunction, turn power off
and on again.
c)
If the above does not solve the problem, the module needs to be
replaced.
d)
A defective module must not be used.
5.5. Repairs
Repairs and inspections of the module can be conducted only by its
manufacturer.