Operators and Maintenance Manual
Measuring module
EMS DAQ R02.01
Page
6/18
Copyright:
Auto & Aero Technologies Sp. z o.o.
Mazowiecka 10/5, 20-723 Lublin, Poland
■
email: info@aatech.pl
■
www.aatech.pl
using non-original parts and subassemblies voids the warranty, relieves the
supplier from any liability, making the device lose the status of the product
of Auto & Aero Technologies Sp. z o.o. with all the resulting consequences.
2. Handling in transport and storage
1.
The EMS DAQ R02.01 module is bubble-wrapped to protect it
against vibration and other physical damage, and packed in a
cardboard box together with the warranty card.
2.
The display must be stored and transported assuring that:
o
the ambient temperature stays in the range of 10
40
°C
o
the ambient relative humidity stays in the range of 10
90 %,
safe from condensation.
3.
The display should be protected from water.
3. Installation
3.1. Environmental specifications
The EMS DAQ R02.01 module has been designed to be installed in engine
compartment of ultralight aircrafts of ceiling not exceeding 3 000 m
(10 000 ft). Acceptable ranges of operating parameters are listed below:
Operating temperature:
-20
o
C
50
o
C
Short-term operating temperature: -25
o
C
60
o
C
Humidity:
0
95 %, no condensation;
Ambient air pressure:
45
105 kPa;
Vibrations:
<5 g at frequencies below 150 Hz;