background image

 

2.1 Mounting to the Yaw Pole 

Slide the yaw pole onto the yaw shaft of the head assembly and fastened by four 
bolts M8/15 with flat washers and lock washers. 

 
2.2 Mounting the Rotor Hub

 

1.  Remove the nut, lock washer and flat washer from the alternator shaft; 
2.  Slide the rotor hub onto the alternator shaft and put on the flat washer and 

lock washer; 

3.  Thread and tighten the nut. The nut should be tightened to 70-85 Nm. 

 
2.3 Mounting the Rotor Blades 

1.  Blades should be in front of the rotor hub, with the flat side facing upwind. 
2.  Insert three bolts in the holes on the hub and blade. Place flat washers on 

the end of the bolts, thread and tighten Nylock self-locking nut. Nuts 
should be tightened to 8-12 Nm. 

 
2.4 Attaching the Front Cover 

Place the spinner over the center of the hub. Thread the M6*35bolt with the lock 
washer and flat washer into the screw hole on the alternator shaft and tighten by 
hex key (Allen wrench). 
 

1.  Drill through the tower tube to the electric wire 

 

 
2.  Attach the wind turbine head assembly 

 

 
 
 
 

Summary of Contents for PowerMax+ 400

Page 1: ...INSTALLATION MANUAL 400W OFF GRID TURBINE...

Page 2: ...with a mass distribution that ensures the rotors operate with nearly no noise and minimal vibration Wind Solar hybrid controller to work with both wind turbine and solar panels Low Start up and cut in...

Page 3: ...1 Package Contents Check the crate packaging Call your PowerMax reseller to report any damage or missing parts...

Page 4: ...shown in above picture We stock either a Weld on Ring Collar or bolt on pole collar Part Number Description Quantity Usage 1 Generator Assembly 1 2 Rotor Blade 3 3 Rotor Hub 1 4 Front Cover 1 5 Front...

Page 5: ...to 70 85 Nm 2 3 Mounting the Rotor Blades 1 Blades should be in front of the rotor hub with the flat side facing upwind 2 Insert three bolts in the holes on the hub and blade Place flat washers on the...

Page 6: ...3 Assemble the wind turbine rotor hub 4 Attach the wind turbine rotor blades 5 Attach the wind turbine front cover 6 Secure the wind turbine screw cover...

Page 7: ...ven if this means placing the turbine farther away from the load than originally planned the increased efficiency of your machine will more than make up for any loss due to distance 4 Tower Recommenda...

Page 8: ...ing and caving If the tower site is located on the loose sand dig a hole of 30 in diameter and 5 feet deep Fill the base with 2 feet of compressed rock or clay tamp that down and add 2 feet of concret...

Page 9: ...cations PowerMax 400 PowerMax 600 Height of Tower Tower Diameter Tower Diameter Tower Wall Thickness Radius of Guy Wire 8 meters 80mm 100mm 3 5mm 4 6m 6 meters 60mm 80mm 3 4mm 4m Dimension of Tower Ba...

Page 10: ...5 Cable Wiring The basic wiring diagram of single PowerMax system is as shown...

Page 11: ...eters 100 150 meters Cable Size 12 AWG 4mm2 10 AWG 6mm2 8 AWG 10mm2 6 Maintenance The PowerMax is a very reliable series and is designed to run for long periods without any maintenance under severe co...

Reviews:

Related manuals for PowerMax+ 400