4
Basic Operations
- 4.8
Sensitivity Adjustment and Inspection Mode
25
44.8.
Sensitivity Adjustment and Inspection Mode
The inspection mode has four different modes
:
Table 33 IInspection Mode
No.
Name
Description
I
Deficiency mode
Mode to detect shortages.
Ex.
:
Deoxidants
*
1
(shortage) etc.
II
Continuous mode
Mode for inspecting unpackaged material, etc.
III
Individual Packaging mode
(PE sensor used)
Individual packaging mode which uses photo-electric (PE) sensor.
IV
Individual Packaging mode
(PE sensor not used)
Individual packaging mode which does not use PE sensor.
Ex.
:
Transparent products, thin products
Note
*
1
Deoxidants are chemicals which change to a deoxygenated state in a sealed vessel.
The inspection can start after the product registration and sensitivity adjustment are complete.
Performing product registration requires a user level of "
Supervisor
" or higher.
Warning
Perform a safety check on the belt and areas surrounding the AD-4971 before operation.
Ensure clothes or other loose items do not get caught in the AD-4971.
Stop the AD-4971 immediately if the gear cover is removed during operation.
Stop the AD-4971 immediately if the electric motor generates excessive heat or produces
unusual sounds
Avoid any shock, impact or excessive load to the conveyor belt during operation.
Caution
It may not be possible to achieve stable inspections immediately after operation starts due to
noise generated by the machine starting up.
1. Touch the "
Sensitivity
" button in the "
Product setting
" screen (Tab). The "
Sensitivity
" screen is displayed.
If the "
Stop
" icon is touched, the "
Product setting
" screen (Tab) is displayed.
If the "
Return
" icon is touched, the previous screen is displayed.
2. Input the belt speed (Range: 10 to 60 m/min) and touch the "
OK
" button.
3. Input the product length (Range: 10 to 1000 mm) and touch the "
OK
" button
4. Check the settings and touch the "
Start to set sensitivity
" button.
5. Inspect the products passing through the sensor on the conveyor belt according to instructions on the screen.
"
Shortage mode
" and "
Individual Packaging (PE sensor used)
"
When the product is passed through, the inspection executes automatically.
"
Continuous mode
" and "
Individual Packaging (PE sensor not used)
"
Touch the "
OK
" button when the product has passed through the sensor.
Summary of Contents for AD-4971
Page 1: ...1WMPD4002757B ...
Page 6: ...4 13 3 Phase Tracking 77 13 4 Rotate Direction 78 ...
Page 77: ...12 Specifications 12 2 Dimensions 75 1 12 2 Dimensions ...
Page 81: ...79 MEMO ...
Page 82: ...80 MEMO ...
Page 83: ......