7
Reference Table of Screens and Menu Items
- 7.3
Settings Screen (Common Settings Tab)
47
77.3.1.
DI Settings Screen (Configuration Tab)
3
4
2
1
Fig. 660 D
DI Settings Screen (Configuration Tab)
The item can be changed using the "
Up
" and "
Down
" icons.
No. Name
Scope
Description
1 DI 1
Not inputted
The DI signal is not received (not inputted).
Start of the inspection
When receiving the DI signal, the inspection is started.
End of the inspection
When receiving the DI signal, the inspection is stopped.
Switch of start and end of the
inspection
When receiving the DI signal, the start and stop of the inspection is
switched.
Canceling the stopping of the belt
When receiving the DI signal, the stopping of the belt is canceled.
Cancel error
When receiving the DI signal, an error state is canceled.
Reset count
When receiving the DI signal, the total count is reset.
Peripheral FAIL
When receiving the DI signal, the AD-4971 treats it as a peripheral FAIL.
Forced DO 1
When receiving the DI signal, it is outputted to the DO 1.
Forced DO 2
When receiving the DI signal, it is outputted to the DO 2.
Forced DO 3
When receiving the DI signal, it is outputted to the DO 3.
Forced DO 4
When receiving the DI signal, it is outputted to the DO 4.
Forced DO 5
When receiving the DI signal, it is outputted to the DO 5.
Forced DO 6
When receiving the DI signal, it is outputted to the DO 6.
Forced DO 7
When receiving the DI signal, it is outputted to the DO 7.
Forced DO 8
When receiving the DI signal, it is outputted to the DO 8.
2 DI 2
The same as DI 1.
3 DI 3
The same as DI 1.
4 DI 4
The same as DI 1.
5 DI 5
The same as DI 1.
6 DI 6
The same as DI 1.
7 DI 7
The same as DI 1.
8 DI 8
The same as DI 1.