7
Reference Table of Screens and Menu Items
- 7.3
Settings Screen (Common Settings Tab)
48
77.3.2.
DI Settings Screen (DI Behavior Tab)
2
1
3
Fig. 661 D
DI Settings Screen (DI Behavior Tab)
No.
Name
Scope
Description
1 Delay time
0.00 (0.00 to 9.99 sec.)
The waiting time from a signal input to the sampling of the DI signal for
the next behavior.
2 Chattering
0.00 (0.00 to 9.99 sec.)
The time to prevent chattering of the DI signal.
3 Polarity
Positive, Negative
Logic of the DI signal.
Positive:
When the device connected to "Contact
A
" makes
contact with "
ON
", the DI signal can be received.
Negative: When the device connected to "Contact
B
" makes
contact with "
ON
", the DI signal can be received.
Note
The DI behavior settings can set to DI 1, DI 2, DI 3 and DI 4.
7.3.3.
Function Settings Screen (Function 1 Tab)
3
4
2
1
Fig. 662 FFunction Settings Screen (Function 1 Tab)
No.
Name
Scope
Description
1 FAIL 1
OFF, ON
Judgment of FAIL 1 means a basic failure.
2 FAIL 2
OFF, ON
Judgment of FAIL 2 means that the PE sensor is out of range.
3 FAIL 3
OFF, ON
Judgment of FAIL 3 means that two products are detected.
4 FAIL 4
OFF, ON
Judgment of FAIL 4 means an error from peripherals.
Information
Refer to "
11.2.4. Inspection Results Messages
"
Summary of Contents for AD-4971