8
Modbus Communication
- 8.4
Address for Modbus
60
TTable 110
IInput Register Address
AAddress
O
Output Name
O
Output Range
AAddress
O
Output Name
O
Output Range
30001
IP Address 1 of the metal
detector
0 to 223
30023
Modbus settings
0 to 2
30002
IP Address 2 of the metal
detector
0 to 255
30024
Modbus, slave address
1 to 247
30003
IP Address 3 of the metal
detector
0 to 255
30025
Modbus-RTU, baud rate
0 to 5
30004
IP Address 4 of the metal
detector
0 to 255
30026
Modbus-RTU, parity
0 to 2
30005
Subnet mask 1 of the metal
detector
0 to 255
30027
Modbus-RTU, stop bits
0 to 1
30006
Subnet mask 2 of the metal
detector
0 to 255
30028
Rotation direction
0 to 1
30007
Subnet mask 3 of the metal
detector
0 to 255
30029
Low speed of metal
detector
10.0 to 60.0
30008
Subnet mask 4 of the metal
detector
0 to 255
30030
High speed of metal
detector
10.0 to 60.0
30009
Default gateway 1 of the
metal detector
0 to 255
30031
Low speed of rejecter
10.0 to 60.0
30010
Default gateway 2 of the
metal detector
0 to 255
30032
High speed of rejecter
10.0 to 60.0
30011
Default gateway 3 of the
metal detector
0 to 255
30033
Total count of PASS
0 to 9999999
30012
Default gateway 4 of the
metal detector
0 to 255
30035
Total count of FAIL 1
0 to 9999999
30013
Default printer
0 to 1
30037
Total count of FAIL 2
0 to 9999999
30014
Printer IP address 1
0 to 255
30039
Total count of FAIL 3
0 to 9999999
30015
Printer IP address 2
0 to 255
30041
Total count of FAIL 4
0 to 9999999
30016
Printer IP address 3
0 to 255
30043
Current count of PASS
0 to 9999999
30017
Printer IP address 4
0 to 255
30045
Current count of FAIL 1
0 to 9999999
30018
Serial communication
settings
0 to 2
30047
Current count of FAIL 2
0 to 9999999
30019
Serial communication, baud
rate
0 to 5
30049
Current count of FAIL 3
0 to 9999999
30020
Serial communication,
parity
0 to 2
30051
Current count of FAIL 4
0 to 9999999
30021
Serial communication, data
bits
0 to 1
30053
Rejector rotation direction
0 to 1
30022
Serial communication, stop
bits
0 to 1
CCAUTION
The register ignores the decimal point of data and stores data.
Example: If data is between 0.0 and 99.9, a value between 0 and 999 is inputted and stored in
the register.
Summary of Contents for AD-4971
Page 1: ...1WMPD4002757B ...
Page 6: ...4 13 3 Phase Tracking 77 13 4 Rotate Direction 78 ...
Page 77: ...12 Specifications 12 2 Dimensions 75 1 12 2 Dimensions ...
Page 81: ...79 MEMO ...
Page 82: ...80 MEMO ...
Page 83: ......