8
Modbus Communication
- 8.4
Address for Modbus
61
TTable 111 H
Holding Register Address
AAddress
O
Output Name
O
Output Range
AAddress
O
Output Name
O
Output Range
40001
Product number
1 to 100
40067
DI 1, Delay time
0.00 to 99.99
40002
Group number
1 to 10
40068
DI 2, Delay time
0.00 to 99.99
40003
Language
0 to 1
40069
DI 3, Delay time
0.00 to 99.99
40004
Sleep timer
0 to 99
40070
DI 4, Delay time
0.00 to 99.99
40005
DI 1 setting
0 to 7
40071
DI 5, Delay time
0.00 to 99.99
40006
DI 2 setting
0 to 7
40072
DI 6, Delay time
0.00 to 99.99
40007
DI 3 setting
0 to 7
40073
DI 7, Delay time
0.00 to 99.99
40008
DI 4 setting
0 to 7
40074
DI 8, Delay time
0.00 to 99.99
40009
DI 5 setting
0 to 7
40075
DO 1, Holding time
0.00 to 99.99
40010
DI 6 setting
0 to 7
40076
DO 2, Holding time
0.00 to 99.99
40011
DI 7 setting
0 to 7
40077
DO 3, Holding time
0.00 to 99.99
40012
DI 8 setting
0 to 7
40078
DO 4, Holding time
0.00 to 99.99
40037
DI 1, Chattering prevention
time
0.00 to 9.99
40079
DO 5, Holding time
0.00 to 99.99
40038
DI 2, Chattering prevention
time
0.00 to 9.99
40080
DO 6, Holding time
0.00 to 99.99
40039
DI 3, Chattering prevention
time
0.00 to 9.99
40081
DO 7, Holding time
0.00 to 99.99
40040
DI 4, Chattering prevention
time
0.00 to 9.99
40082
DO 8, Holding time
0.00 to 99.99
40041
DI 1, Delay time
0.00 to 99.99
40083
DO 1, Polarity
0 to 1
40042
DI 2, Delay time
0.00 to 99.99
40084
DO 2, Polarity
0 to 1
40043
DI 3, Delay time
0.00 to 99.99
40085
DO 3, Polarity
0 to 1
40044
DI 4, Delay time
0.00 to 99.99
40086
DO 4, Polarity
0 to 1
40045
DI 1, Polarity
0 to 1
40087
DO 5, Polarity
0 to 1
40046
DI 2, Polarity
0 to 1
40088
DO 6, Polarity
0 to 1
40047
DI 3, Polarity
0 to 1
40089
DO 7, Polarity
0 to 1
40048
DI 4, Polarity
0 to 1
40090
DO 8, Polarity
0 to 1
40049
Stopping setting
0 to
4294967295
40091
PE sensor, Chattering
prevention time
0.00 to 99.99
40051
DO 1 setting
0 to
4294967295
40092
Error time for blocked PE
sensor
0 to 100.0
40053
DO 2 setting
0 to
4294967295
40093
Consecutive FAIL stop,
ON/OFF
0 to 1
40055
DO 3 setting
0 to
4294967295
40094
Consecutive FAIL count
0 to 9999
40057
DO 4 setting
0 to
4294967295
40095
Volume of speaker
0 to 5
40059
DO 5 setting
0 to
4294967295
40096
FAIL buzzer, ON/OFF
0 to 1
40061
DO 6 setting
0 to
4294967295
40097
Inspection start & stop
buzzer, ON/OFF
0 to 1
40063
DO 7 setting
0 to
4294967295
40098
Behavior of count overflow
0 to 1
40065
DO 8 setting
0 to
4294967295
40099
FAIL limit
I
0.1 to 99.9
Summary of Contents for AD-4971
Page 1: ...1WMPD4002757B ...
Page 6: ...4 13 3 Phase Tracking 77 13 4 Rotate Direction 78 ...
Page 77: ...12 Specifications 12 2 Dimensions 75 1 12 2 Dimensions ...
Page 81: ...79 MEMO ...
Page 82: ...80 MEMO ...
Page 83: ......