10
Maintenance and Cleaning
- 10.2
Cleaning
67
Saving the system file.
Store the system file to USB memory.
IInformation
Refer
to
"
11.1.1. Saving the System File
".
10.2.
Cleaning
WARNING
Shut off power to the system before cleaning.
When washing, make sure that the lid of the I/O box is closed.
10.2.1.
Light Dirt
Please be sure to make the following check before and after the inspection.
Cleaning the conveyor belt and the sliding plate
Cleaning the conveyor belt and the sliding plate
Clean with and without water or with alcohol.
Wash AD4971 in water Temperature: 40
䰳
or less, Pressure: 12.5l/min or less.
Check the conveyor belt.
Remove the conveyor belt, check for fraying, warping, abrasion, cracks or any other deformities.
Note
Select the appropriate cleaning depending on the packaging and the product.
10.2.2.
Heavy Dirt
On a regular basis remove the conveyor belt and the sliding plate.
Two tension roller, a drive roller and slave roller
Opening of the sensor head (Especially the underside)
Backside of the conveyor belt
The surface and the backside of the sliding plate
The surface of the frame (Especially the inside of the frame)
For the conveyor belt, clean the following as required.
Wash with neutral detergent
Wash with hypochlorous acid water
Boil for five minutes
WARNING
The conveyor belt should be naturally dried enough after cleaning. There is a possibility that
mold grows.
Please prepare several conveyor belts, if you need.
Summary of Contents for AD-4971
Page 1: ...1WMPD4002757B ...
Page 6: ...4 13 3 Phase Tracking 77 13 4 Rotate Direction 78 ...
Page 77: ...12 Specifications 12 2 Dimensions 75 1 12 2 Dimensions ...
Page 81: ...79 MEMO ...
Page 82: ...80 MEMO ...
Page 83: ......