 51

 

 

 

 

 Click [New patient] to open the New Patient window and register a new patient. 

     

New Patient window

 

 

 

 

 

 

 

 

 

7.  Confirm the patient to be registered and click [Register]. 

 

 

 

 

 

 

 

 

 

 

 

8.  The message “Saved” appears and data registration has been completed. 

 

 

 

 

 

 

 

 

 

 

 

To continue receiving data, click [Next data]. 

 

To complete the operation, click [Close]. 

 

 

These three items are required. 

After entering the necessary items, click [Add]. 

Confirm the patient to be registered.

Click [Register].

The message “Saved” appears. 

Summary of Contents for Doctor Pro 3 TM-9501

Page 1: ...Doctor Pro3 Blood Pressure Data Analysis Software Windows TM 9501 INSTRUCTION MANUAL 1WMPD4001540C ...

Page 2: ...ibed or translated into any language in any form by any means without the express written consent of A D Company Limited The contents of this manual and the specifications of the instruments covered by this manual are subject to change without notice Windows is a registered trademark of the Microsoft Corporation ...

Page 3: ...on The contents of the caution are described inside or near the symbol using text or a picture The example on the left indicates caution against electrical shock The symbol indicates Do not The contents are described inside or near the symbol using text or a picture The example on the left indicates Do not disassemble The symbol z indicates Never fail to The contents are described inside or near t...

Page 4: ...een provided to the customer User by A D Company Limited A D pursuant to the terms and conditions below 1 Definitions 1 1 Software Software refers to the program in a machine readable format that has been recorded as memory data on a master disk and included in this package in addition to the instruction manual and other data that explain the procedure for using the Software 1 2 Use Use refers to ...

Page 5: ...d User Rights All copyrights and user rights regarding materials such as image files and symbols shall be in accordance with those contained in the Software 8 Warranties Only those warranties described below are applicable to the Software Furthermore A D does not warrant that the Software is free of defects 8 1 A D will exchange or replace the CD ROM for the software or other print materials in th...

Page 6: ...in accordance with 10 2 or 10 3 below 10 2 This contract will terminate when the customer disposes of the Software including backup copies and deletes all data previously installed from the Software 10 3 This contract will terminate immediately in the event that the customer disagrees with any of the conditions set forth herein 10 4 The Customer must immediately dispose of the software in the even...

Page 7: ...location for future reference 1 Storage site Avoid the followings as a storage site Areas where the temperature is less than 20 C or greater than 55 C and the relative humidity is over 95 Areas where chemicals are stored Areas where exposed to direct sunlight 2 Maintenance Inspect cables before use and periodically When a cable is used after a long period of storage confirm that the device is func...

Page 8: ...c waves In a room or building where the device is used turn off cellular phones and other small radio units High frequency noise from other devices via an electrical outlet Detect the source of the noise and take measures to break the route using a noise suppressor Avoid using the noise generating device Use another electrical outlet Static electricity Fully discharge the operator before use Humid...

Page 9: ...tained by detecting the Korotkoff sounds Oscillometric Oscillometric method Blood pressure values are obtained by analyzing variations in pulse pressure detected in the cuff Systolic SYS SBP Systolic Blood Pressure Maximum blood pressure or the blood pressure when the heart is contracting Diastolic DIA DBP Diastolic Blood Pressure Minimum blood pressure or the blood pressure when the heart is rela...

Page 10: ... of Correlation Reg Line Regression Line Histogram c i Confidence Interval Interval surrounded by the confidence limit of 95 Terms and abbreviations related to circadian rhythm Description Cosinor Circadian rhythm analysis method introduced by Halberg et al 1967 MESOR A circadian rhythm adjusted mean based on the parameters of a cosine function fitted to the raw data AMP Amplitude Amplitude of a c...

Page 11: ...tegral of the blood pressure values not reaching the user defined limits HBI sys The limits of the systolic blood pressure to HBI HBI dia The limits of the diastolic blood pressure to HBI F Full analysis P Partial analysis Approximate Curve Fourier Series Expansion Order meas measurement AVERAGE Trend Average trend shows the trend of hourly average values for systolic blood pressure diastolic bloo...

Page 12: ...x Blank Page ...

Page 13: ... 3 Connecting the UB 511USB to the computer 11 5 MAIN WINDOW 12 6 GENERAL OPERATION 13 6 1 Starting up Doctor Pro3 13 6 2 Receiving the Data 13 6 3 Selecting or Adding a Patient 15 6 4 Analyzing the Measurement Data 16 6 5 Printing the Data 18 7 NEW PATIENTS 20 8 MANAGING DATA 23 8 1 Editing the Group List 24 8 1 1 Add group 24 8 1 2 Rename group 24 8 1 3 Search 24 8 2 Editing the Patient List 25 ...

Page 14: ...each analysis window 47 9 RECEIVING DATA 49 10 SENDING THE SETTINGS 52 10 1 Automatic Recognition of the Blood Pressure Monitor 52 10 2 Device Information and Measurement Intervals 53 10 3 Confirming the Settings and Data Transmission 55 11 FILE MENU 56 11 1 Importing Files 56 11 2 Exporting Files 58 11 3 Optimizing a Database 59 12 CONFIGURATION 60 12 1 Medical Facility 60 12 2 Account Mode 61 12...

Page 15: ...4 1 Error Codes 70 14 1 1 TM 2430 70 14 1 2 Guidance messages 71 14 2 Default Settings 72 14 3 Disposing of the Used Product 72 15 CUSTOMER SUPPORT 73 15 1 Inquiries about the Product 73 15 2 Disclaimer 73 ...

Page 16: ...or y UA 767PC ME Medical Electronics Digital Blood Pressure Monitor with communication function y UB 511USB HHC Home Health Care Wrist Digital Blood Pressure Monitor with communication function Doctor Pro3 has the following features Patient data management The blood pressure data and patient information are saved in a personal computer database The data is separated into groups Statistical analysi...

Page 17: ...are package components are damaged or missing contact the local A D dealer you purchased the product from CD ROM 1 disk USB cable AX KO3057 200 TM 2430 and UA 767PC 1 piece Instruction manual 1 copy This document CD ROM USB cable AX KO3057 200 for TM 2430 and UA 767PC Instruction manual Doctor Pro3 Blood Pressure Data Analysis Software 䋨㪮㫀㫅㪻㫆㫎㫊䋩 TM 9501 INSTRUCTION MANUAL 1WMPD4001540 ...

Page 18: ...7PC Bi directional communication with a personal computer Penables data analysis and date setting using the Data Analysis Software Stores 280 sets of measurement data Clock and calendar function Alarm can be set up to 6 times a day Useful for monitoring blood pressure treatment and conducting various clinical trials research on blood pressure and home based monitoring systems UB 511USB Compact and...

Page 19: ... Ambulatory Blood Pressure Monitor is used to record an individual s blood pressure over an extended period normally 24 48 hours The monitor employs the oscillometric method to record the patient s blood pressure based on predetermined periods and parameters The user may divide each 24 hour interval into several periods Within each period the monitor may be programmed to record the patient s blood...

Page 20: ... to step 5 Otherwise click the Start button on the Windows taskbar and select Run 3 Type g setup g is the hard disk drive into which the CD ROM will begin installations 1 The following appears when the USB driver has not been installed Connect the USB cable supplied with the software to your personal computer and click Setup FTDI USB Device Driver 2 Specify the CD ROM Driver folder and install the...

Page 21: ... 4 Install Doctor Pro3 Follow the instructions in the display 5 When Doctor Pro3 has been installed successfully the message Setup succeeded appears Click OK then click Exit to quit the installation mode ...

Page 22: ...anteed 4 2 1 Connecting the TM 2430 to the computer Use the USB cable supplied with the software otherwise communication errors will occur Connection between the TM 2430 and the computer The illustration above is not to scale Connect the blood pressure monitor to a personal computer as follows 1 Insert the male end mini pin jack of the USB cable into the monitor 2 Insert the male end USB A plug of...

Page 23: ...her functions 3 Start up Doctor Pro3 4 2 3 Connecting the UB 511USB to the computer Use the USB mini B plug USB A plug USB cable otherwise communication errors will occur Connection between the UB 511USB and the computer The illustration above is not to scale Connect the blood pressure monitor to a personal computer as follows 1 Insert the male end USB mini B plug of the USB cable into the monitor...

Page 24: ... Select from Import Export Optimize a DB or Exit Quick Same with the quick startup menu Configuration Select from Medical facility Account mode New account Default settings Measurement pattern settings or Change language Window Select the window displaying method Help Displays the software version information Tool bar No Name Description 5 Quick menu Turns ON or OFF the quick startup menu 6 New pa...

Page 25: ...he START menu or Click the DrPro3 icon located on the desk top 2 The Main window opens 6 2 Receiving the Data Receives the measurement data from the blood pressure monitor For details refer to Section 9 RECEIVING DATA 1 Click Receive data at the quick startup menu Receive data Quick startup menu Quick startup menu ...

Page 26: ... the message Successfully received data appears in the Connect Device window Click Next TM 2430 recognition UA 767PC recognition UB 511USB recognition 4 The data received is displayed Click Next 5 The Select Patient window opens Click Next Click Next ...

Page 27: ... to register a new patient When the patient selection is completed click Next 2 Confirm the patient to be registered Click Register and then click OK in the Confirm window 3 When the display shown below appears the patient has been registered To complete the operation click Close To continue receiving data click Next data Select a patient To select a new patient register a new patient Click Next C...

Page 28: ... startup menu 2 Select the patient data from the group list 3 Click the registration date to be analyzed from the Data Registration window The list of measurement data will be displayed in the Measurement Data window Open database Quick startup menu Group list Data Registration window Measurement Data window Patient list registered in each folder ...

Page 29: ...s can be analyzed For details refer to 8 6 Data Analysis Window Menu Refer to Select periods 8 6 1 Summary data 8 6 2 Trend 8 6 3 Correlation 8 6 4 Histograms 8 6 5 Circadian rhythm 8 6 6 HBI analysis 8 6 7 AVERAGE trend 8 6 8 Select periods Summary data Trend Correlation Histograms Circadian rhythm HBI analysis AVERAGE trend ...

Page 30: ...Awake tab window Æ Click Print to print y Sleep tab window Æ Click Print to print Printing in the Trend window y Individual printing Æ Prints a trend graph y Print all Æ Click boxes as necessary in Graph option to print and select the printing parameters from the pulldown menu Printing in the Correlation window y Individual printing Æ Prints correlation plots y Print all Æ Click boxes as necessary...

Page 31: ...nting in the HBI Analysis window y Individual printing Æ Prints HBI analysis plots y Print all Æ Click boxes as necessary in Graph option to print and select the printing parameters from the pulldown menu Printing in the AVERAGE Trend window y Individual printing Æ Prints an hourly average trend graph y Print all Æ Click boxes as necessary in Graph option to print and select the printing parameter...

Page 32: ...atient s last name using a maximum of 30 characters Sex Select from the pulldown menu Date of birth Enter in the MM DD YYYY format or select from the pulldown menu Select group Required Point the mouse to the group folder To add a group or rename the group click the Add group or Rename group icon or right click to display Add group and Rename group When all the necessary items have been entered cl...

Page 33: ... the doctor s name using a maximum of 30 characters Medications Enter the patient s medications using a maximum of 60 characters Comment 1 Enter comments using a maximum of 200 characters Comment 2 Enter comments using a maximum of 200 characters Pattern of meas Pattern of measurement Select from the pulldown menu When all the necessary items have been entered click Next 4 Past Illness window Item...

Page 34: ...22 5 Confirm window Click OK to register the new patient ...

Page 35: ...tient database Click Open database at the quick startup menu Patients Database window Click a folder in the group list The relevant data is displayed in the patient list Open database Quick startup menu Group list Patient list Closes this window ...

Page 36: ...roup 1 Click the folder into which a group will be added 2 Click the Add group icon 3 A new folder is added 4 Enter the group name 8 1 2 Rename group Note Patient names can not be changed 1 Click a folder to rename 2 Click the Rename group icon 3 Enter a group name 8 1 3 Search 1 Click the Search icon to open the Search Data window 2 Enter search items 3 Click Search 4 The search results will be d...

Page 37: ... 2 Click the New patient icon to open the Simple Registration window Enter the following items y Patient ID Required y First name Required y Last name Required y Date of birth y Sex When all the necessary items have been entered click Register 3 The Confirm window opens 4 Click OK to add the patient Click Close to complete the operation ...

Page 38: ...ived Device Displays the model of the blood pressure monitor that was used W Wake time Displays the wake time B Bedtime Displays the bedtime Select Click the box to include in data analysis CSV Displays a data format 2C CSV imported data format of Doctor Pro2 2D DAT imported data format of Doctor Pro2 3C CSV imported data format of Doctor Pro3 Blank Standard measurement data NOTE The CSV column is...

Page 39: ...splays statistical data Trend 8 6 3 Displays systolic blood pressure diastolic blood pressure mean arterial blood pressure pulse heart rate and double product trends Correlation 8 6 4 Displays correlation plots of systolic blood pressure to diastolic blood pressure and diastolic blood pressure to pulse The scatter diagram allows easy observation of the correlation between systolic and diastolic bl...

Page 40: ...ing the user defined limits for the sleep and awake sections Hypobaric that area not reaching the user defined limits for the sleep and awake sections Note Not available with the UA 767PC and UB 511USB AVERAGE trend 8 6 8 Displays the trend of hourly average values for systolic blood pressure diastolic blood pressure mean arterial blood pressure and pulse heart rate Ascending order Sorts the regis...

Page 41: ...ents Only for the TM 2430 Displays the measurement during sleep or manual measurement Always 0 for the UA 767PC UB 511USB Meas method Measurement method Displays the measurement method Korotkoff or oscillometric Errors Displays individual errors Displays error codes for the TM 2430 Always 0 for the UA 767PC UB 511USB Suppressed Click the data to exclude from data analysis Comments Enter comments u...

Page 42: ...30 8 4 1 Switching the measurement data window Clicking the icon in the Measurement Data window switches the window as follows BP Data List window Simple Trend window ...

Page 43: ... the patient s personal information and device information The Patient Information window has three tabs Meas info tab to edit the device information Personal details tabs to edit the patient s personal information Patient Information window ...

Page 44: ... from the pulldown menu Buzzer Select from the pulldown menu Meas pattern Pattern of measurement Select from the pulldown menu Height Enter the patient s height in 0 99999 Place a decimal point as necessary Weight Enter the patient s weight in 0 99999 Place a decimal point as necessary Address Enter the patient s address using a maximum of 50 characters Telephone Enter the patient s telephone numb...

Page 45: ...a 8 6 1 Select periods Sets the analysis period of the data selected in the Data Registration window Without selecting periods analysis will not be performed 1 Select Total or Total Interval Analysis for the analysis period 2 Set the starting date and time and the period using the scroll bars Select periods Summary data Trend Correlation Histograms Circadian rhythm HBI analysis AVERAGE trend ...

Page 46: ...n the data in the specified period Awake Statistics based on the data during the waking hours Note Waking hours are specified as those hours outside the identified sleeping hours Sleep Statistics based on the data during the specified sleeping hours Note Sleeping hours are specified as those hours outside the identified waking hours To open print and close the Summary Data window follow the proced...

Page 47: ...period MAX Maximum The maximum value for Systolic Diastolic MAP and Pulse measurements during the analysis period SD Standard Deviation The Standard Deviation of the value for Systolic Diastolic MAP and Pulse measurements during the analysis period SE Standard Error The Standard Error of the value for Systolic Diastolic MAP and Pulse measurements during the analysis period CV Coefficient of Variat...

Page 48: ... A vertical solid line connects the measurement s systolic and diastolic pressures This line may be used to estimate the pulse pressure Pulse Pulse Trend The vertical axis represents beats per minute bpm and the horizontal axis represents time The pulse trend is represented by yellow dots Mean Arterial Blood Pressure MAP Trend The vertical axis represents millimeters of mercury mmHg and the horizo...

Page 49: ...data analysis Two periods full analysis and partial analysis may be defined for each data file 5 Close Closes the Trend window 6 Left right arrows Moves the cursor to the left or right 7 Config graph Changes the graph axes settings 8 Select graph Click the box to display the graph or if there is a check mark in the box and no graph is needed click the box to remove the check mark 9 Suppressed data...

Page 50: ... vertical axis represents mmHg bpm 1000 and the horizontal axis represents time Icons in the Trend window No Icon Description 1 Individual printing Prints a trend graph 2 Print all Opens the Conclusion Printing window Select graph options set printing parameters and click Print 3 List Disp Not Disp Selects whether or not to display the list of measurement data below the trend graphs 4 Select perio...

Page 51: ...t r Regression Line The vertical axis represents systolic pressure the horizontal axis represents the diastolic pressure on the left hand graph and pulse on the right hand graph All the graphs have scales of 0 to 300 mmHg Note If Partial Analysis is enabled four graphs will appear The first two graphs in the upper part of the window in blue are based on Full data The second pair of graphs in red i...

Page 52: ...stograms based on Full data are indicated in blue and the Histograms created from valid data specified within Partial Analysis parameters are indicated in red The vertical scale represents 0 to 300 mmHg or bpm on all graphs except Double Product The horizontal scale represents the percentage of total readings that occurred at the corresponding vertical level The Histograms are displayed in blocks ...

Page 53: ...g time coincides with the starting time specified for the Full Analysis period The Circadian Rhythm window also shows the amplitude and peak value of the cosine wave based on the 95 confidence interval The systolic blood pressure data is indicated in red the diastolic blood pressure data in blue and the pulse data in yellow Click the Close icon or X in the upper right corner to close the Circadian...

Page 54: ...ical data converted into a one day period The lower graph shows the hypobaric area in red not reaching the user defined hypobaric limits for the systolic and diastolic blood pressures and the numerical data converted into a one day period For both graphs the analysis starting time coincides with the starting time specified for the Full Analysis period Click the Close icon or X in the upper right c...

Page 55: ...nd window shows the trend of hourly average values for systolic blood pressure diastolic blood pressure mean arterial blood pressure and pulse heart rate Click the Close icon or X in the upper right corner to close the AVERAGE Trend window ...

Page 56: ...stration window 8 7 1 Printing procedure from the print preview window 1 Select the registration date and click the Print preview icon 2 Click boxes as necessary in Graph option to print and select the printing parameters from the pulldown menu 3 Click Preview Print preview Print all ...

Page 57: ...en all the items are selected in Graph option Page 1 Summary Trend Page 2 List Page 3 Correlation Page 4 Histograms Page 5 Circadian rhythm Page 6 HBI analysis Page 7 AVERAGE trend 5 Click the Print all icon The Conclusion Printing window opens 6 Change the settings in the Conclusion Printing window if necessary 7 Click Print ...

Page 58: ... Click the Print all icon 2 Click boxes as necessary in Graph option to print and select the printing parameters from the pulldown menu Select Mini report to print the summary data trend and data list Select Trend DP to print the trend of double product 3 Click Print ...

Page 59: ...rinting in the Trend window y Individual printing Æ Prints a trend graph y Print all Æ Click boxes as necessary in Graph option to print and select the printing parameters from the pulldown menu Printing in the Correlation window y Individual printing Æ Prints correlation plots y Print all Æ Click boxes as necessary in Graph option to print and select the printing parameters from the pulldown menu...

Page 60: ...as necessary in Graph option to print and select the printing parameters from the pulldown menu Printing in the HBI Analysis window y Individual printing Æ Prints HBI analysis plots y Print all Æ Click boxes as necessary in Graph option to print and select the printing parameters from the pulldown menu Printing in the AVERAGE Trend window y Individual printing Æ Prints an hourly average trend grap...

Page 61: ...r the UA 767PC UB 511USB While the PC is in communication with the blood pressure monitor appears in the blood pressure monitor display For details refer to the blood pressure monitor instruction manual Receive data Quick startup menu Clearing the data When Clear data is selected the data in the monitor will be cleared after receiving the data Adjusting the time When Adjust time of ABPM is selecte...

Page 62: ...in 5 The data received is displayed Click Next 6 Specify a file folder to save the data Select from the list of registered patients the patient under whose name you would like to save data When a new patient is to be used register the new patient beforehand Click Next The message Successfully received data appears Select a patient file folder When a new patient is to be used register the new patie...

Page 63: ...istered and click Register 8 The message Saved appears and data registration has been completed To continue receiving data click Next data To complete the operation click Close These three items are required After entering the necessary items click Add Confirm the patient to be registered Click Register The message Saved appears ...

Page 64: ...menu The Send Setting Data window opens 2 Click Next The connected blood pressure monitor is automatically recognized 3 When a connection has been completed a message appears Auto detection of TM 2430 Auto detection of UA 767PC Auto detection of UB 511USB Confirm that the monitor model is correct Click Next Send setting data Quick startup menu The message Successful automatic recognition of the BP...

Page 65: ...easurement is performed every 30 minutes Mode 3 The measurement intervals can be set within a maximum of 24 hours Select from different measurement patterns TM 2430 Device Information window 1 Enter Recorder ID 2 Select the items below from the pulldown menu y Cuff size y Display y Clear data y Adjust time Click Next Measurement Intervals window Select a mode from Modes 1 3 When Mode 3 is selected...

Page 66: ... starting time in hours and the starting time in minutes from the pulldown menu and click the Valid box to use When a measurement pattern which is set in Measurement pattern settings is to be used click the Select Pattern box and select a pattern from the pulldown menu Click Next UB 511USB Device Information window Select the items below from the pulldown menu y Clear data y Adjust time Click Next...

Page 67: ... transmission has started A message appears when the transmission has been completed Sent to TM 2430 Sent to UA 767PC Sent to UB 511USB To continue sending data click Next To complete the operation click Close The message Setting successful appears Confirm the settings Click Apply when the settings are correct ...

Page 68: ...he DrPro2 3 CSV Exports Files and DrPro2 DAT Exports Files can be used 11 1 Importing Files 1 Click Import from the File menu of the Main window 2 Click Import Click the Import to box to specify the importing destination folder 3 Specify the importing destination folder and click Import Click Import Click Import ...

Page 69: ...57 4 Select the importing source folder Select a file and click Open The file has been imported to the specified folder 1 Select the importing source folder 2 Select a file 3 Click Open ...

Page 70: ... Search 3 Select data to export from the list displayed 4 Select the items below y Number of files to output Separate file s Merge files y File type DrPro3 CSV DrPro2 CSV DrPro2 DAT 5 Click Export 6 Select the exporting destination folder and enter a file name Click Save The file has been exported 1 Select the exporting destination folder 2 Enter a file name 3 Click Save ...

Page 71: ...59 11 3 Optimizing a Database 1 Click Optimize a DB from the File menu of the Main window 2 The Confirm window opens Click OK to optimize the database ...

Page 72: ...nfirm window opens Click OK to register the medical facility Item Description First name Enter the first name using a maximum of 30 characters Last name Enter the last name using a maximum of 30 characters Hospital name Enter the hospital name using a maximum of 50 characters Address Enter the hospital address using a maximum of 50 characters Telephone Enter the hospital telephone number using a m...

Page 73: ...unt or multi account and click Register The Confirm window opens Click OK to change the account mode 12 3 New Account 1 Click New Account from the Configuration menu of the Main window 2 Enter account names and passwords for multi accounts Select authority Click New save or Delete to add update or delete the account ...

Page 74: ...f the user changes to the multi account mode and restarts logging in will no longer be available because the account and password have not been registered If the condition above occurs enter the items below to log in Account Administrator Password sys 12 4 Default Settings 1 Click Default Settings from the Configuration menu of the Main window ...

Page 75: ...the time axis from the pulldown menu For UA 767PC and UB 511USB Priority display Select from the pulldown menu Hyperbaric limit for systolic in awake section Enter the value Hyperbaric limit for diastolic in awake section Enter the value Hyperbaric limit for systolic in sleep section Enter the value Hyperbaric limit for diastolic in sleep section Enter the value Hypobaric limit for systolic in awa...

Page 76: ...gs from the Configuration menu of the Main window 2 Set measurement patterns for Mode 3 Enter each item and click Register The Confirm window opens Click OK to set the measurement pattern To delete a setting click Delete and click OK for the message Delete Item Description Name Name the measurement pattern Start time Hour Select a measurement starting time in hours from the pulldown menu Start tim...

Page 77: ... 6 Changing Languages 1 Click Change Language from the Configuration menu of the Main window 2 In the Change Language window select the language to be used and click OK Changing languages has been completed ...

Page 78: ...INDOW MENU The Window menu has the following sub menus y Cascade y Horizontal y Vertical y Minimization 13 1 Cascade 1 Click Cascade from the Window menu of the Main window The opened windows will be cascaded ...

Page 79: ...k Horizontal from the Window menu of the Main window The opened windows will be arranged horizontally Note When more than three windows are opened the Horizontal and Vertical functions arrange the opened windows in the same way ...

Page 80: ...ck Vertical from the Window menu of the Main window The opened windows will be arranged vertically Note When more than three windows are opened the Horizontal and Vertical functions arrange the opened windows in the same way ...

Page 81: ...zation from the Window menu of the Main window An opened window will be reduced to an icon To restore the window to the original size double click on the reduced icon Or click the icon and select Restore to the original size or Maximize ...

Page 82: ...o not move and try to relax during the measurement If the error persists repair is necessary E07 Forced stop using STOP key Do not press the STOP key unless necessary E08 E10 Pulse can not be detected Do not move and try to relax during the measurement E20 Pulse is less than 35 beats or more than 200 beats per minute Measure the blood pressure by other methods E21 Diastolic is greater than 160 mmH...

Page 83: ...ition of ABPM failed Failed to receive data Failed to read measurement settings Failed to read measurement data Failed to erase measurement data Failed to setup the clock y Confirm that the communication cable is connected to the blood pressure monitor y Confirm that the USB driver is functioning correctly y Disconnect all the cables Restart Doctor Pro3 y Messages when data is sent Message Correct...

Page 84: ...tings The window below shows the default settings that have been set before shipment 14 3 Disposing of the Used Product When disposing of or recycling this product follow your local regulations to protect the environment ...

Page 85: ...l damages or losses which occur in connection with the furnishing performance or use of this product Further A D Company Limited does not accept liability in any of the following circumstances Damage caused by maintenance or repair by an unauthorized dealer Damage caused by not obeying the precautions described in the instruction manual Damage caused by not using the measurement conditions describ...