8
5. CONFORMING STANDARDS
5-1. IECEx
Ex ia op is
ΙΙ
B T3 Ga Tamb -25°C to
+40°C (IECEx FMG 17.0033X)
Ex: Ex
Component
ia:
Type of Protection
ΙΙ
B: Gas
Classification
T3: Temperature
Class
Ga: Equipment
Protection
Level
5-2. ATEX
ΙΙ
1G Ex ia op is
ΙΙ
B T3 Ga Tamb -25°C to
+40°C (FM17ATEX0096X)
Ex: Ex
Component
ia:
Type of Protection
ΙΙ
B: Gas
Classification
T3: Temperature
Class
Ga: Equipment
Protection
Level
5-3. FM, FMc (Zone)
Class
Ι
, Zone 0, AEx / Ex ia op is
ΙΙ
B T3 Tamb -25°C to
+40°C
(FM17US0317X/FM17CA0162X)
Class: Permitted
Class
Zone: Permitted
Zone
Ex: Ex
Component
(AEx:
American National Standard)
ia:
Type of Protection
ΙΙ
B: Gas
Classification
T3: Temperature
Class
5-4. FM, FMc (Division)
Intrinsically Safe for Class
Ι
, Division 1, Groups C, D T3C
Tamb -25°C to
+40°C (FM17US0317X/FM17CA0162X)
Intrinsically Safe: Type of Protection
Class: Permitted
Class
Division: Permitted Division
Groups: Permitted
Groups
T3C: Temperature
Class