ACAI
10. ACAI FUNCTION
10. ACAI FUNCTION
10. ACAI FUNCTION
10. ACAI FUNCTION
10-1. ACAI
10-1. ACAI
10-1. ACAI
10-1. ACAI
Automatic Counting Accuracy Improvement
Automatic Counting Accuracy Improvement
Automatic Counting Accuracy Improvement
Automatic Counting Accuracy Improvement
The ACAI
TM
(Automatic Counting Accuracy
Improvement) function recalculates the unit
weight as more pieces are added to improve
count accuracy.
When the scale calculates unit weight from
sample pieces, the more sample pieces that
are used, the higher the accuracy.
ACAI Notes
ACAI Notes
ACAI Notes
ACAI Notes
q
You must do the ACAI procedure just after you set the unit weight. Samples must be still
on the weighing pan.
q
Do not take the samples off until the end of the ACAI procedure.
q
You don’t have to count out the pieces when you add, just stay within the ACAI range.
q
Continue the ACAI procedure to reach the largest amount that you will be counting.
q
If you want the most precise counting results for every different batch of the same items,
use ACAI every time you start counting the next batch.
q
The ACAI does not work when you use a remote scale if the unit weight was set on the
main scale and vice versa.
q
The ACAI function is initially set to manual operation when the unit weight is set digitally
by the keyboard, by ID memory or using computer via the serial interface. This can be
set to the automatic mode. The ACAI mode when unit weight is entered by ID or digital
input is controlled by F-Function
f-02-02
. It is initially set at “
0
”, ACAI manual operation
mode. Set to “
1
” for automatic operation mode.
10-2. ACAI Automatic Operation
10-2. ACAI Automatic Operation
10-2. ACAI Automatic Operation
10-2. ACAI Automatic Operation
1. To start ACAI automatic
operation, unit weight must
be registered and the sample
still on the weighing pan.
2. Add pieces within the
nearest ACAI range (refer to
table below). A good rule of
thumb is to roughly double
the amount on the weighing
pan.
STABLE
#
#
#
#
#
#
#
88888
28
&&
F?I
!
A A
W E I G H T ( k g )
1213456789
3.108
!
2 3 4 A 5 6 U
U W ( g )
12314567
111.000
ZERO
TOTAL
M+
TARE
ENTERED
SCALE
ACAI
SAMPLE
TOO LIGHT