81
1 2
3 4
MODE
ON
1 2
3 4
MODE
ON
16-2.
Connection to peripheral equipment
16-2-1. Connection To The AD-8121B Printer
Preset the following parameters to use the AD-8121B printer.
Class
Item and Parameter Factory
settings
AD-8121B
MODE 1
AD-8121B
MODE 2
AD-8121B
MODE 3
prt
Data output mode
0
0
,
1
,
2
3
0
,
1
,
2
ap-p
Auto print polarity
0
ap-b
Auto print difference
1
#1
Not
necessary
#1
d-no
Data number output
0
0
0
0
,
1
5-td
Time/Date output
0
0
0
0
,
1
,
2
,
3
5-id
ID number output
0
0
0
0
,
1
pU5e
Data output pause
0
0
0
0
,
1
#2
dout
Data output
at-f
Auto feed
0
0
0
0
,
1
bp5
Baud rate
2
2
2
2
btpr
Data bit, parity bit
0
0
0
0
Crlf
Terminator
0
0
0
0
type
Data format
0
0
0
1
5if
Serial
interface
Ct5
CTS, RTS control
0
0
0
0
#1 Set parameters when auto print mode A or B (
prt 1
or
2
) is selected.
#2 Set
1
when multiple lines are printed. Example: When appending ID number, set
1
.
Settings of AD-8121B
MODE
AD-8121B
DIP switch
Description
MODE 1
1 2
3 4
MODE
ON
Print at receiving data.
Standard mode, statistic mode
MODE 2
1 2
3 4
MODE
ON
Print by DATA key operation or built-in timer.
Standard mode, interval mode, chart mode
MODE 3
1 2
3 4
MODE
ON
Print at receiving data.
Dump print mode
DIP switch No.3 : Handling unstable data
ON
OFF
Not
printed
DIP switch No.4 : Data input specifications (Interface selection)
ON
Current
loop
OFF
RS-232C
The printer performs as follows, depending on the data memory setting.
Setting Output
data
data 0
The weighing data
data 2
The weighing data stored in memory
data 3
The calibration report stored in memory
Refer to "11-2. GLP Report" for print samples.
GF-K series does not output the time and date. Use the calendar function of the AD-8121B.