Function Table of Balance 

The function table stores parameters that specify how to operate the balance, and it is used to 

monitor or update those parameters. These parameters are stored in memory even if the AC 

adaptor is removed and are retained until overwritten. Balance operations are specified by this 

table when using the GXM

-

04

/

GXL

-

04 and the GXM

-

06

/

GXL

-

06. The table menu consists 

of two layers as shown in the diagram below. The first layer is the “

Class

” and the second layer 

is the “

Item

”. Each item stores a "

Parameter

". The last displayed parameter is in effect. After 

the    PRINT    key is pressed, these updated parameters are applied to operations of the 

balance.   

Example of settings and menu structure (Example: the GXM

-

04) 

Example : Set to "

Center value using sample weight input

" of "

Input method

" in "

Comparator

". 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caution

 

The balance may not function properly, depending on the settings and the operating 

environment. Be sure to set parameters correctly.

 

5.1.

 

Operation Keys and Display of Function Table 

  The

 

 

indicates that the parameter displayed is in effect.   

 

Enters the function table when pressed and held in the weighing mode.   

Selects the class or item in the function table. 

 

 Changes the parameter. 

 

Moves to an item in the class when a class is displayed. 

Stores the new parameter and displays the next class when an item is displayed. 

 

Cancels new parameter and displays the next class when an item is displayed.  

Exits the function table and returns to the weighing mode when a class is displayed. 

Press 

 with the GX

-

M

/

GF

-

M series and 

  with the GX

-

L

/

GF

-

L series. 

Start from weighing mode 

Class 

Finish to weighing mode 

Press and hold 

Press 

Item 

Input method 

Press 

Parameter 

Center value using numerical input 
 

Parameter 

Center value using sample weight 

1

 

Summary of Contents for GX-L Series

Page 1: ...1WMPD4003912B GXM 04 GXL 04 GXM 06 GXL 06 COMPARATOR OUTPUT ANALOG VOLTAGE OUTPUT...

Page 2: ...duced transmitted transcribed or translated into any language in any form by any means without the written permission ofA D Company Ltd The contents of this manual and the specifications of the instru...

Page 3: ...9 6 GXM 04 GXL 04 Comparator Output 12 6 1 Specifications of Comparator Output 12 6 2 Using the Comparator Output 13 6 3 ComparisonMethodSelection Tolerance Range and Center Value or Threshold Values...

Page 4: ...equipped with six contact outputs HH HI OK LO LL of the comparison output and READY output to indicate the status of the balance 3 stage comparison or 5 stage comparison can be selected The GXM 04 GXL...

Page 5: ...llowing procedure The installation procedure of the GXM 04 and GXM 06 is the same Step1 Remove the two screws from the panel and remove the RS 232C USB board from the balance Step2 Pull gently and rem...

Page 6: ...e balance Step2 Pull gently and remove the two cables from theRS 232C USB board Step3 Insert the two cables into the sockets of the GXL 06 board Step4 Insert the rubber packing and plug the GXL 06 int...

Page 7: ...d terminal Step3 Cover the terminal with the top metal case and bottom metal case Step4 Fasten wires with the top metal case Step5 Insert the assembled parts into the rubber sleeve Rubber sleeve Top m...

Page 8: ...to Center value using sample weight input of Input method in Comparator Caution The balance may not function properly depending on the settings and the operating environment Be sure to set parameters...

Page 9: ...ts from zero Comparison excluding 20 digits counts from zero Comparison excluding 50 digits counts from zero Comparison excluding 100 digits counts from zero Polarity Comparison of positive values onl...

Page 10: ...yed when 5 stage comparison is selected Upper limit Lower limit Second lower limit Center value Refer to explanation of 6 GXM 04 GXL 04 Comparator Output Referencevaluewhenusingthedatainputmethod or i...

Page 11: ...interface Analog output Analog output mode 2 digit output mode Displayed only when the GXM 06 GXL 06 are connected 3 digit output mode Net full scale output mode Gross full scale output mode Output di...

Page 12: ...male Accessory E8 200J 100 or equivalent Externalcontact input connector Compatibleplug 3 5mm3pole ministereojack MP 013LC or equivalent parts Panel External View Example The GXM 04 Thepanel externalv...

Page 13: ...One is the method using second upper limit upper limit lower limit and second lower limit Another is the method using center value and tolerance range There two types of input methods for second uppe...

Page 14: ...tting Centervalue using numerical input or Centervalue using sample weight Procedure Step1 Press and hold the SAMPLE key to enter the function table is displayed Step2 Press the SAMPLE key to display...

Page 15: ...old value is displayed the current parameters are displayed all digits blinks Numerical input of threshold values If Step6 If changing the parameters press the RE ZERO key to store the following keys...

Page 16: ...table is displayed Step2 Press the SAMPLE key several times to display comparator threshold value Step3 Press the PRINT key to display comparator threshold value Step4 Pressthe SAMPLE keyseveraltimest...

Page 17: ...e PRINT key while displaying The current parameter is displayed If the tolerance range is to be changed change it using the following keys Input the tolerance range with center value assumed to be 100...

Page 18: ...to 0V 0 2 V to 1 V With the slide switch set to 0 2V Input impedance of 10 k or greater the device connected Output update To be updated depending on the cycle of display rewriting The cycle is change...

Page 19: ...t using the RE ZERO key Gross full scale output mode Outputs 0 000 V when the gross weight is zero Outputs 1 000 V when the gross weight is full scale Tare operation using the RE ZERO key will not aff...

Page 20: ...V 0 456 V 0 345 V 0 234 V 0 023 V 0 002 V If or Model GX M GF M series Full scale GX 8202M GX 8202MD GF 8202M GF 8202MD 8 kg GX 10202M GF 10202M 10 kg GX 12001M GF 12001M 12 kg GX 22001M GF 22001M 22...

Page 21: ...100 V 10 kg Caution Full scale of the full scale output mode indicates the full scale values shown in the tables above The output voltage may exceed 1 000 V depending on the weighing value Example Whe...

Page 22: ...stment and a voltmeter voltage output can be finely adjusted Procedure Step1 Turn off the display using the ON OFF key Voltage output becomes zero point status Adjust the ZERO volume so that the voltm...

Page 23: ...rload is displayed 0 V is output or 0 2 V if the slide switch is set to 0 2V Step4 When E weighing value is positive overload is displayed the following voltages are output Example Voltage output when...

Page 24: ...arton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 07331 817 Manhattan Bldg 33 Gukjegeumyung ro 6 gil Yeongdeungpo gu Seoul 07331 Korea 82 2 78...

Reviews: