35
F-06-X RS-232C Data Output
F-06-X requires OP-03 or OP-04 RS-232C interface.
Data Out Mode
0
3
Key Mode: Data is sent by pressing the
key.
+ Command Mode.
1
Stream Mode: Data is sent continuously.
Command Mode cannot be used.
2
Auto-Print Mode A: Data is sent if the weight display is stable
at +5d (weighing display division) and above.
+ Command Mode.
3
Auto-Print Mode B: Data is sent if the weight display is
stable, at ±5d (weighing display division) and above/below.
+ Command Mode
4
Command Mode Only.
5
This setting cannot be used.
6
UFC format with Key Mode (see setting “
0
”).
7
UFC format with Auto-Print Mode A (see setting “
2
”).
8
UFC format with Auto-Print Mode B (see setting “
3
”).
Data to be Sent.
0100
3
Count data sent.
You select which data to be sent by keying in a
0
or
1
for the data: ID no., PCS (count),
weight or unit weight.
Example:
Key in
1
1
0
0
to display
1100
,
this setting would send only the ID number and
the count.
Data Format
When
f-06-01
=“
6
”, “
7
” or “
6
” is set, the data is UFC format.
0
3
Format for AD-8121 MODE 1. Same as
f-06-03
=“2” but the
interval between continuous data is approximately 2 seconds.
1
Format for AD-8121 MODE 3. The interval between continuous
data is approximately 2 seconds.
2
Format for general apparatuses, computers, etc.
The data-update rate is approximately 10 times per second
when used with the Stream Mode.
Baud Rate
0
3
2400 bps.
1
4800 bps.
2
9600 bps.
0000
Weight
PCS(count)
Unit
ID Weight
f-06-02
f-06-04
f-06-01
f-06-03
Summary of Contents for HC-30Ki