background image

 

1

SAFETY PRECAUTIONS 

All safety messages are identified by the following, 

“WARNING”

 or 

“CAUTION”

, of ANSI Z535.4 (American National Standard Institute: 

Product Safety Signs and Labels). The meanings are as follows: 

 

    WARNING 

    A potentially hazardous situation which, if not   
    avoided, could result in death or serious injury. 

    CAUTION 

    A potentially hazardous situation which, if not   
    avoided, may result in minor or moderate injury. 

 

‰

 This manual is subject to change without notice at any time to improve the 

product. 

‰

 Product specifications are subject to change without any obligation on the 

part of the manufacture.   

‰

 When using the HL-WP, the following safety precautions should always be 

followed. 
 

WARNING  Use only the specified AC adapter for the scale. Other 

adapters may cause damage (The AC adapter is optional). 
Internal service or adjustments to this product should be 
performed by a qualified person. 

 

CAUTION 

Avoid installing the scale in direct sunlight, which may cause 
discoloration or malfunctions. 
Do not mix the type of batteries. Replace all the batteries at the 
same time. 
If the scale is not to be used for a long period of time, remove 
all batteries from the battery compartment to avoid leakage. 
Avoid overloading that could cause damage to the scale. 
Avoid using the weighing pan to move the scale, as that could 
cause damage to the scale. 
When the scale is used with an AC adapter, the scale does not 
conform to IP-65 protection. 

I P 6 5  

 
 
 

 

 

 

Degree of protection against water: Protected against water jets.

Degree of protection against solid foreign objects: Dust-tight. 

IP Code (Degree of protection provided by enclosures) of IEC 60529

Summary of Contents for HL-WP Series

Page 1: ...HL 1000WP HL 300WP HL 3000WP HL 3000LWP 1WMPD4000754B Digital Scale HL WP Series This document hosted by www oldwillknottscales com...

Page 2: ...AC adapter for the scale Other adapters may cause damage The AC adapter is optional Internal service or adjustments to this product should be performed by a qualified person CAUTION Avoid installing...

Page 3: ...tery cover Battery compartment AC adapter jack Batteries are not included Rubber cap Battery cover lock U S A models only 04 76 3k oz 04l12 3k oz 0 1 000k lb 01200 0kg STABLE indicator Indicates when...

Page 4: ...put requirement could be 100 120 220 230 or 240 volts 50 60Hz depending on the area where used so please verify that the adapter is correct Plug the AC adapter to the AC adapter socket inside the batt...

Page 5: ...ress the ON OFF key to turn on the scale Then the scale displays all segments for a few seconds and then 0 will be displayed 2 Start weighing If you do not use a container for weighing Verify the read...

Page 6: ...2g HL 3000WP 3000g 0 2g HL 3000LWP 3000g 0 2g 1 Enter calibration mode Press the ON OFF key to turn the power off While pressing both the RE ZERO key and the UNITS key press the ON OFF key Cal will be...

Page 7: ...value 1 Enter calibration mode Press the ON OFF key to turn the power off While pressing both the RE ZERO key and the UNITS key press the ON OFF key Cal will be displayed 2 Select a digit to be change...

Page 8: ...lb 950 g 2 1 lb Calibration weight 1000g 0 1g 300g 0 02g 3000g 0 2g Accessories This manual Options AC adapter The Value of Gravity at Various Locations Amsterdam 9 813 m s2 Manila 9 784 m s2 Athens...

Page 9: ...8 World Map...

Reviews: