Step 7 Arrange the cable so it does not touch the weighing
pan in the base unit.
If the cable is untied, the straight length of S
-
models
is approximately
1.5
m, and the straight length of
M
-
models and L
-
models is approximately
2.5
m.
The length of the optional extension load cell cable
(HVW
-
08C) is approximately
5
m.
Step 8 Remove the pole and bracket from the base unit
using a hex wrench.
Hex wrench
5
mm HV
-
15KC, HV
-
15KCP, HV
-
60KC,
HV
-
60KCP,
HW
-
10KC, HW
-
10KCP, HW
-
60KC, HW
-
60KCP
Hex wrench
6
mm HV
-
200KC, HV
-
200KCP, HW
-
100KC, HW
-
100KCP,
HW
-
200KC, HW
-
200KCP
Step 9 Wind the cable through the ferrite core two times.
Affix the cable to the rear cover using the cable clamp.
Step 10 Connect the cable to the connector.
Close the rear cover.
Step 11 Check the weighing accuracy.
Extension load cell cable (HVW
-
08C)
Display
unit
5
m extension cable
The shape of base unit differs by model.