Page 38
HV-WP/HW-WP Series
13. Simple Batch Function
Caution
The parameters of the upper limit value (HI) and a final value (HI) use the
same memory. The parameters of the lower limit value (LO) and the
preliminary value (OK) use the same memory.
The upper/lower comparator function, the simple batch function and the
full/dribble batch function can not be used at the same time because these
parameters use common memory.
13.1. Preparation (Setting Parameters)
Step 1 Turn off the display.
Press
the
ON/OFF
switch while the
ZERO
switch is
pressed and held. The function table is displayed.
Step 2 Press the
ENTER
switch to display an item of the
comparator function (
f6
).
Step 3 Select a parameter of the simple batch function
(
f6 8
) with the
∧
switch.
Step 4 Press the
ENTER
switch and the
F
switch to display
end .
Step 5 Press the
ENTER
switch to return to the normal
weighing mode.
Summary of Contents for HW-200KV-WP