HV-WP/HW-WP Series
Page 47
15. The Function Table
Item
Display
Meaning and purpose
A
f9
Not used
The details of the full/dribble batch function (
f6 9
)
A
f10 0
#
Reaching final value and pressing the
F
switch, the current
process is finished.
A
A
f10 1
Reaching final value and displaying the stability mark, the current
process is finished automatically.
A
A
f10 2
Pressing the
SET
switch, the scale automatically tares and starts
the full/dribble batch process. Reaching final value and pressing
t
he
F
switch, the current process is finished.
A
A
A
Full/Dribble
batch
sub-func-ti
on
f10 3
Pressing the
SET
switch, the scale automatically tares and starts
the full/dribble batch process. Reaching final value and
displaying the stability mark, the current process is finished.
A
A
A
Address for RS-422 / RS-485 for option OP-04
A
f11 00
#
Address
f11 01
~
f11 99
Use This address can be set from 01 to 99. It is possible for a
computer to control the scale assigned an address.
(RS-232C should be set to "
00
".)
A
A
A
The function to hold the current display value. When the value
becomes nearly-zero or the weighing value changes more than
25% +30 digits, hold display is canceled.
A
A
A
f12 0
# Not used
A
f12 1
The hold function is ON or OFF alternately by the
F
switch.
A
Hold
f12 2
Displaying the stability mark, the display is held.
A
Selects readability and response.
A
f13 0
# Fast response, sensitive value
A
f13 1
Ú
A
Averaging
f13 2
Slow response, stable value
A
Selects a storable minimum unit mass in the counting mode.
A
f14 0
# Stores a unit mass in the unit of a digit.
A
f14 1
Stores a unit mass in the unit of one eighth digit.
A
Precision
of unit
mass
f14 2
Stores a unit mass, if the total of the sample mass is greater than
5 digits.
A
A
Refer to "16.1. Data Format".
A
f15 0
# Format 1. (A&D general format for scales, balances)
A
f15 1
Format 2. (Older HV-A/ HW-A format)
A
f15 2
Not used
Format
f15 3
Format 1 (Return command is available for all commands.)
f16
Not used.
A
f17
The function number “
f17
” is not displayed.
When displaying
000000
, press the
ENTER
switch to cancel.
The "#" is factory settings
The "nearly-zero" is within
±
5 digits from zero point in the unit of kg.
The "digit", a unit of display, is equivalent to the minimum measurable mass.
Summary of Contents for HW-200KV-WP
Page 72: ...Page 70 HV WP HW WP Series MEMO...