2. Overview of Communication Control
Communication for RA2000 series (1WMPD4003507)
2-2
2.1. Local/Remote Control
►
The RA2000 Series has two control modes: 1) a local mode that
allows control through the control panel and the touch panel, and 2)
a remote control mode that allows control only through the
communication port.
2.1.1. Local Mode
This is the default state after the power is turned on. Control can be performed either by the control
panel and the touch panel, or by input from the remote terminal.
2.1.2. Remote Control Mode
If data is received when a communication function is selected, the RA2000 goes into the remote
control mode. Moreover, when a specified auto-transmission cause is generated, the mode enters
into the remote control mode. At this time, it is possible to control the RA2000 from the
communication interface.
●
Data reception other than [NUL] occurs
When the RA2000 is switched to remote control mode,
recording continues
and the
remote
control mode screen
is displayed. In the remote control mode,
all controls performed via the
control/touch are ignored.
Local mode
Remote control mode
or
2.1.3.Returning to Local Mode
The mode returns to the Local mode upon the reception of escape sequence command
[ESC]-Z
.
Please click the above-shown “Keylock” icon to return manually to local mode.
2.2. Overview of the Communication Commands
►
Communication commands to control the RA2000 Series remotely
are categorized into three types.
●
Character string command
Controls such as settings and recordings are basically performed by string commands. The
string commands consist of a 3-character command and parameter string following the
command.
●
Escape Sequence Commands
The [ESC]+1 character is used as a command. By using these commands, operation/error
information of the RA2000 Series can be obtained. This command cannot control settings and
operation of the RA2000 Series recorder.
●
1 Byte Control Command
Execution is possible by sending a 1-byte control code alone, but functions are limited. The
above-mentioned character string commands and escape sequence commands have
functions of equal or higher quality.
Summary of Contents for Omniace RA2000 series
Page 1: ...Communication Command RA2000 series INSTRUCTION MANUAL 1WMPD4003507 ...
Page 2: ......
Page 3: ...Communication Command RA2000 series INSTRUCTION MANUAL ...
Page 4: ......
Page 14: ......
Page 15: ...1 Selection of Communication Interface ...
Page 27: ...2 Overview of Communication Control ...
Page 34: ......
Page 35: ...3 Setting Command s ...
Page 63: ...4 Information Readout Command I ...
Page 90: ......
Page 91: ...5 Execution Command E ...
Page 99: ...6 File Data Operation Command F ...
Page 102: ......
Page 103: ...7 Text Operation Command T ...
Page 109: ...8 Reference ...
Page 113: ......