3. Setting Command – s**
Communication for RA2000 series (1WMPD4003507)
3-23
3.13. Other Settings
STR (Set TRans CH.) Setting real-time transfer channel
SIM (Set Input Monitor) Setting display speed of input monitor
SAT (Set Auto Transmit) Setting transmit function
Function
Sets real-time transfer channel.
STR P1, P2 (Delimiter)
Input Format
P1: Specifying channel
P2: ON/OFF
[1-16, E1, E2, A] for RA2300MK
Ⅱ
[1-32, E1, E2, A] for RA2800A
A means a batch setting.
(0=OFF, 1=ON)
Output Format
None
Description
Real-time transfer is executed with the “ETS Execute Real-time data trans”
Function
Sets display speed of input monitor.
SIM P1, P2, P3 (Delimiter)
Input Format
P1: Speed numeric value
P2: Speed unit
P3: Switch
([0-1000] step 1 0=External synchronization
(Can be omitted)
(0=[us/div], 1=[ms/div], 2=[s/div], 3=[min/div])
(Can be omitted)
(0=input monitor, 1=chart, 2=memory recording,
3=HD recording) (Can be omitted)
Output Format None
Description
When all parameters are omitted, a parameter error occurs.
The current recorder mode limits the switch selected with P3.
The cases in which a switch is allowed are below. (When it is disallowed, a
mode error occurs.)
Recorder mode
Input
monitor
Chart
Memory
recording
HD
recording
Pen recorder
Enabled Enabled Disabled
Disabled
Memory recorder
Enabled
Disabled
Enabled
Disabled
HD recorder
Enabled Enabled Disabled
Enabled
Multi recorder
Enabled Enabled Enabled Enabled
X-Y recorder
Enabled
Disabled
Disabled
Disabled
Data recorder
Enabled
Disabled
Disabled
Disabled
Function
Sets transmit function.
SAT P1, P2 (Delimiter)
Input Format
P1: Record error occurrence 0=No transmit 1=Transmit
P2: Transmit during recording 0=No transmit, 1=Transmit after
recording is finished, 2=Transmit when trigger is detected.
Output Format
None
Description
When the specified cause occurs, “!” is output from the RA2300MK
Ⅱ
.
The detailed cause can be confirmed with the “ICA Inquire auto transmit
CAtion”
Summary of Contents for Omniace RA2000 series
Page 1: ...Communication Command RA2000 series INSTRUCTION MANUAL 1WMPD4003507 ...
Page 2: ......
Page 3: ...Communication Command RA2000 series INSTRUCTION MANUAL ...
Page 4: ......
Page 14: ......
Page 15: ...1 Selection of Communication Interface ...
Page 27: ...2 Overview of Communication Control ...
Page 34: ......
Page 35: ...3 Setting Command s ...
Page 63: ...4 Information Readout Command I ...
Page 90: ......
Page 91: ...5 Execution Command E ...
Page 99: ...6 File Data Operation Command F ...
Page 102: ......
Page 103: ...7 Text Operation Command T ...
Page 109: ...8 Reference ...
Page 113: ......