background image

5 Frame ground 

FG 

4 Signal ground 

SG 

3  Data set ready 

DSR 

2 Transmit data 

TXD 

1 Receive data 

RXD

 

Terminal block J1 

4 Relay output common  COM 

3 Relay output 

LO 

2 Relay output  

OK 

1 Relay output  

HI

 

Terminal block J2 

 

D-Sub 9 Pin Connector 

D-Sub 9 pin Connector 

Connections 

SEC-03, Terminal block J1

Pin 

Signal name 

 

Pin

Signal name 

1 DCD 

 

   

2 RxD 

 

2

TxD 

3 TxD 

 

1

RxD 

4 DTR 

 

   

5 SG 

 

4

SG 

6 DSR 

 

3

DSR 

7 RTS 

   

8 CTS 

Shorted  

 

 

 

 

 

Blank heat shrink tubing covered wire   

5

FG 

 
 

AX-KO3341-320

 

 
 
 
 
 
 
 
 
 
 

3. SCE-03 RS-232C Serial Interface 

  The RS-232C serial interface has four output modes; Stream mode, Command mode, Print switch 

mode and Auto-print mode. For details, refer to “

3.3. Data output mode

”. 

  Set the parameters of the functions “ 

bp5

 ”, “ 

prt

 ” and “ 

aCk

 ” as necessary. 

 

3.1. Interface specifications 

  Data format  Baud rate: 

2400, 4800, 9600 bps 

   

Data bits: 

7 bits + parity 1 bit (even) 

  

Start 

bit: 

bit 

   

Stop bit: 

1 bit 

  

Code: 

ACII 

  

Terminator:  

C

L

F

    (

C

R

: 0Dh, 

L

F

: 0Ah) 

 

 

 

LSB 

 

 

 

 

 

5

MSB

6

 

 

 

 

 
 
 
 
 

  Relay output maximum rating 

  

Maximum 

voltage: 

50V 

DC 

   

Maximum current: 

100mA DC 

  

Maximum 

ON 

resistance: 

8

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.2. Data format 

S  T  ,  +  0  0  0  0  0  .  0  0  _ k g C

R

  L

F

 

 

 

  Four types of headers are available:

 

ST

  : Stable weight data 

US

  : Unstable weight data (including counting data) 

QT

  : Stable counting data 

OL

  : Out of weighing range

 

  The data is always 9 digits including a sign and a decimal point. 

  Four units are available:

 

_kg

  : Weight data in “kilograms” (kg) 

_lb

  : Weight data in “decimal pounds” (lb) 

_PC

  : Counting data in “pieces” (pcs) 

_oz

  : Weight data in “decimal ounces” (oz) 

  The terminator is always 

C

L

F

  Example of output data: 

 

Weight data “kg” 

S  T  ,  +  0 0 1 2 3 .  4 5 _ k g C

R

  L

F

 

 

Counting data “pcs” 

Q  T  ,  +  0 0 0 1 2 3 4 5 _ P C C

R

  L

F

 

 

Out of weighing range “kg” (

+

O  L  ,  +  9 9 9 9 9 .  9 9 _ k g C

R

  L

F

 

 

Out of weighing range “pcs” (

-

O  L  , 

-

9 9 9 9 9 9 9 9 _ P C C

R

  L

F

 

 
 

3.3. Data output mode 

 

Stream mode / Command mode

 Function 

setting 

 

prt

 

0

 ”

 

  The scale outputs the current display data in sync with the display update of approximately 10 times per 

second. The scale does not output data while it is in the setting mode.

 

 

Command mode only 

Function setting “

 

prt

 

1

 

 

  The scale replies only to a command

.

 For details, refer to “

3.4. Command mode

”.

 

1 (-15V~-5V) 

0 (5V~15V)   

Stop bit

 

Parity bit 

Data bits 

Start bit

 

Header

Data 

Unit 

Terminator 

Separator 

Note:  “_” indicates a space.

 

1.Brown 

2.Red 

3.Orange 

4.Yellow 

5.Green 

6.Blue 

7.Purple 

8.Gray 

9.White 

10.Black 

RXD

TXD 

DSR 

SG 

FG

 

SCE-03

Terminal block J1

 

Optional cable unit   

to connect with   

AD-8121B printer (3 m)

 