Example: 
 
 

Operation Mode 

 

Measurement with storing data

 

( Refer to page 7)

 

 Press 

the 

START

 

button. Blood pressure is measured and data is stored 

within the device. The device can store the last thirty sets of data for each   
button.  

 

 

Recalling data

 

 

Press and hold the 

START

 button to recall the 

data. Stored data are automatically displayed in 
order from the last data.   

 

 

Clearing data

 

  Remove battery to clear all data. Re-install it again. 

 
 
 

WHO Classification Indicator 

  Each of the six segments of the bar indicator corresponds to the WHO blood 

pressure classification described on the next page. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pressure Bar Indicator 

  The indicator monitors the 

progress of pressure during 
measurement. 

 
 
 
 
 
 
 
 
 
 
 
 
 

The indicator displays a segment,
based on the current data,
corresponding to the WHO
classification.

 

:

 

Inflation complete

 

Pressurizing

 

Measurement in progress

 

Releasing air

Inflation in progress

 

WHO Classification Indicator 

Severe hypertension 
Moderate hypertension 
Mild hypertension 
High normal 
Normal 
Optimal 

Moderate 

hypertension

 

Data number 

Stored Data 

Alternation 

Press and hold

Summary of Contents for UA-705

Page 1: ...Digital Blood Pressure Monitor Model UA 705 Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni 1WMPD4000988B...

Page 2: ...Measurement Operation 6 After Measurement 6 Measurements 7 Measurement With Storing Data 7 Notes For Proper Measurement 8 Operation Mode 9 WHO Classification Indicator 9 Pressure Bar Indicator 9 What...

Page 3: ...use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be avoided Clean t...

Page 4: ...English 3 Parts Identification...

Page 5: ...surement until exhaust is complete Press the exhaust valve button to exhaust air from the cuff Flashes when pressure is insufficient for the measurement Pump air into the cuff with the rubber bulb Pre...

Page 6: ...attery if the device is not to be used for a long time The battery may leak and cause a malfunction The stored data are cleared when the batteries are removed Connecting The Air Hose Insert the air co...

Page 7: ...right after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Try to measure your blood pressure at the same time every day Measurement Operation During measu...

Page 8: ...hen the mark disappears Note If you want to stop inflation at any time stop squeezing the rubber bulb and press the exhaust valve button to expel the air from the cuff 4 When inflation is complete def...

Page 9: ...ter of the cuff will be at the same height as your heart Relax for about five or ten minutes before taking a measurement If you are excited or depressed by emotional stress the measurement will reflec...

Page 10: ...ain WHO Classification Indicator Each of the six segments of the bar indicator corresponds to the WHO blood pressure classification described on the next page Pressure Bar Indicator The indicator moni...

Page 11: ...h arterial blood pressure if left unattended can cause many health problems including stroke and heart attack Hypertension can be controlled by altering one s lifestyle avoiding stress and with medica...

Page 12: ...Battery polarities are not in the correct position Reinstall the battery with its negative and positive end matching those indicated in the battery compartment The cuff is not fastened properly Fasten...

Page 13: ...functioning and accuracy Please contact either your authorized dealer or A D for maintenance Technical Data Type UA 705 Measurement method Oscillometric measurement Measurement range Pressure 20 280...

Page 14: ......

Reviews: