background image

 

 

English  4

 

 

Symbols 

 

Symbols 

Function / Meaning 

Recommended Action 

 

Standby and ON switch. 

 

 

 

Battery installation guide 

 

 

SN 

Serial number 

 

 

 

Date of manufacture 

 

 

 

Type BF: Device, cuff and tubing are 

designed to provide special protection 

against electrical shocks. 

 

 

 

The indicator that appears while 

measurement is in progress. It blinks 

when the pulse is detected. 

Measurement is in 

progress. Remain as still 

as possible. 

 

I

rregular 

H

eart

b

eat indicator. (I.H.B.) 

The indicator that appears when an 

irregular heartbeat or any excessive 

body movement is detected during the 

measurement. 

 

 

 

Flashes when there is air remaining 

in the cuff at power up.   

Flashes at the completion of the 

measurement until exhaust is complete.

Press the exhaust 

valve button to 

exhaust air from the 

cuff. 

 

Flashes when pressure is insufficient 

for the measurement. 

Pump air into the cuff 

with the rubber bulb. 

 

Previous measurements stored in 

memory. 

 

 

   Full Battery

 

Indicates remaining battery power.   

 

 

  low Battery

 

Blinks when battery is low. 

Replace battery with 

new one when the 

indicator blinks. 

Unstable blood pressure due to 

movement during the measurement. 

Try the measurement again.

Remain very still during 

the measurement. 

The systolic and diastolic values are 

within 10 mmHg of each other. 

 

The pressure value did not increase 

during inflation. 

 

The cuff is not fastened correctly. 

 

PUL. DISPLAY ERROR 

The pulse is not detected correctly. 

Check the air hose 

connecter plug and cuff. 

Fasten the cuff correctly, 

and try the 

measurement again. 

 

EC directive medical device label 

 

 

 

WEEE label 

 

 

 

 

 

Summary of Contents for UA-705

Page 1: ...Digital Blood Pressure Monitor Model UA 705 Instruction Manual Manuel d instructions Manual de Instrucciones Manuale di Istruzioni 1WMPD4000988B...

Page 2: ...Measurement Operation 6 After Measurement 6 Measurements 7 Measurement With Storing Data 7 Notes For Proper Measurement 8 Operation Mode 9 WHO Classification Indicator 9 Pressure Bar Indicator 9 What...

Page 3: ...use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust should be avoided Clean t...

Page 4: ...English 3 Parts Identification...

Page 5: ...surement until exhaust is complete Press the exhaust valve button to exhaust air from the cuff Flashes when pressure is insufficient for the measurement Pump air into the cuff with the rubber bulb Pre...

Page 6: ...attery if the device is not to be used for a long time The battery may leak and cause a malfunction The stored data are cleared when the batteries are removed Connecting The Air Hose Insert the air co...

Page 7: ...right after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Try to measure your blood pressure at the same time every day Measurement Operation During measu...

Page 8: ...hen the mark disappears Note If you want to stop inflation at any time stop squeezing the rubber bulb and press the exhaust valve button to expel the air from the cuff 4 When inflation is complete def...

Page 9: ...ter of the cuff will be at the same height as your heart Relax for about five or ten minutes before taking a measurement If you are excited or depressed by emotional stress the measurement will reflec...

Page 10: ...ain WHO Classification Indicator Each of the six segments of the bar indicator corresponds to the WHO blood pressure classification described on the next page Pressure Bar Indicator The indicator moni...

Page 11: ...h arterial blood pressure if left unattended can cause many health problems including stroke and heart attack Hypertension can be controlled by altering one s lifestyle avoiding stress and with medica...

Page 12: ...Battery polarities are not in the correct position Reinstall the battery with its negative and positive end matching those indicated in the battery compartment The cuff is not fastened properly Fasten...

Page 13: ...functioning and accuracy Please contact either your authorized dealer or A D for maintenance Technical Data Type UA 705 Measurement method Oscillometric measurement Measurement range Pressure 20 280...

Page 14: ......

Reviews: