RZ Series Feature String Nomenclature
G
E
N
M
JR
E
V
S
IZ
E
S
E
R
IE
S
M
N
R
E
V
V
L
T
A1
A2
A3
A4
A5
B1
B2
B3
B4
B5
1
2
3A
3B
3C
3D
3
E
4A
4B
4C
5A
5B
5C
5D
5E
6A
6B
6C
6D
6E
7
8
9A
9B
9C
9D
RZ A - 145 - D 0 - 3 - C A B 0 A
-
0 0 0 0 0 : N 0 - A A K A Q - J 0 0 - B F T 0 M - 0 0 0 0 0 - Q F - A 0 A A
- 0 0
-
M 0 - C - 0 0 0 -
8 0 - D A 0 B - 0 0
-
0 0 0 - A B E Q 0 A - E 0 0 0 0 0 - 0 0 0 0 0 D B
10
A
10
B
11A
11B
12
13A
13B
13C
14
15
16A
16B
16C
16D
17A
17B
18A
18B
18C
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
14: SAFETY OPTIONS
0 = Standard
A = RA & SA Firestat
B = RA Smoke Detector
C = SA Smoke Detector
D = High Supply Air Static Pressure Switch
E = Remote Safety Shutdown Terminals
F = Option A + B
G = Option A + C
H = Option A + D
J = Option A + E
K = Option B + C
L = Option B + D
M = Option B + E
N = Option C + D
P = Option C + E
Q = Option D + E
R = Option A + B + C
S = Option A + B + D
T = Option A + B + E
U = Option A + C + D
V = Option A + C + E
W = Option A + D + E
Y = Option B + C + D
Z = Option B + C + E
1 = Option B + D + E
2 = Option C + D + E
3 = Option A + B + C + D
4 = Option A + B + C + E
5 = Option A + B + D + E
6 = Option A + C + D + E
7 = Option B + C + D + E
8 = Option A + B + C + D + E
15: ELECTRICAL ACCESSORIES
0 = Standard
B = Phase & Brown Out Protection
C = Air Disinfection UV Lights
E = Compressor Sound Blankets
K = Option B + C
M = Option B + E
P = Option C + E
15: ELECTRICAL ACCESSORIES
Continued
Z = Option B + C + E
Feature 16: UNIT CONTROLS
16A: CONTROL SEQUENCE
0 = Standard Terminal Block for Thermostat
A = Terminal Block for Ther Isolation
Relays
B = Single Zone VAV Unit Controller - VAV Cool +
CAV Heat
C = Single Zone VAV Unit Controller - VAV Cool +
VAV Heat
D = VAV Unit Controller - VAV Cool + CAV Heat
E = Constant Air Volume Unit Controller - CAV
Cool + CAV Heat
F = Makeup Air Unit Controller
M = Field Installed DDC Controls by Others
N = Field Installed DDC Co Isolation Relays
P = Factory Installed DDC Controls by
Isolation Relays
16B: CONTROL SUPPLIER
0 = Standard
A = AAON Controls
C = AAON Controls Supervisory
16C: CONTROL SUPPLIER OPTIONS
0 = Standard
16D: BMS CONNECTION & DIAGNOSTICS
0 = None
B = BACnet MSTP
K = BACnet MSTP with Diagnostics
Feature 17: PREHEAT OPTIONS
17A: PREHEAT CONFIGURATION
0 = No Preheat
17B: PREHEAT SIZING
0 = No Preheat