3.2.3
The concrete floor shall be free from any cracks or defects, and should have been dried for at least 28 days.
3.2.4
Pre-embedded anchor bolts are not required.
3.2.5
Keep the working site dry, clean and �dy.
Founda�on concrete with wrong dimensions, poor construc�on, insufficient concrete thickness or absence of
drainage is not allowed to be used for installing parking
hoist
,
Advance AutoQuip 2000
takes no liability for any
injuries or losses
caused by the above as a consequence.
3.3
Deciding the orientation
Before assembly or installa�on commenced, you can choose the way of orien�ng your
hoist.
This will affect where
to place the Power Pack and Key Switch (control panel), which are NOT interchangeable.
The le� plan in below is the standard configura�on, the main post where power pack and key switch mounted is at
the entrance side, so that all the works including control, opera�ng, maintenance to power pack are done in front.
(2) Founda�on Diagram
4199
500
500
5399
4199
600
100
5399
500
500
Ground surface
!
Entrance Direction
05
AL
2525 &
AL
2625