FOUNDATION
DEIMENSIONS IN CM
QUALITY OF
CONCRETE
MIN.
PRESSURE
RESISTANCE
OF SURFACE
MAX. REACTION
ON EACH
BEARING POINT
Length
Width
Thickness
25MPA
425
2
Kg/cm
0.9
2
Kg/cm
1500
1500
1
50
Chapter 7 Installation
Only skilled technicians, appointed by the manufacturer, or by authorized dealers, must be
allowed to carry out installation. Serious damage to people and to the lift can be caused if
installations are made by unskilled personnel.
Before carrying out any operations, remember to insert the safety piece of wood
between the lower booms and the base frame.
7.1 Checking for room suitability
The lift has been designed to be used in covered and sheltered places free of overhead obstructions.
The place of installation must not be next to washing areas, painting workbenches, solvent or varnish
deposits. The installation near to rooms, where a dangerous situation of explosion can occur, is strictly
forbidden. The relevant standards of the local Health and Safety at Work regulations, for instance, with
respect to minimum distance to wall or other equipment, escapes and the like, must be observed.
7.2
Lighting
Lighting must be carried out according to the effective regulations of the place of installation. All area
next to the lift must be well and uniformly lit.
7.3 Installation surface
The lift must be placed on level floor and sufficiently resistant. The surface must be suitable for bearing
maximum stress values, also in unfavorable working conditions. For installations on raised surface,
compliance with the maximum carrying capacity of the surface is recommended.
A level floor is suggested for proper installation. Small differences in floor slope
may be compensated for by proper shimming. Any major slope change will affect
the level lifting performance. If a floor is of questionable slope (more than 3mm
side to side or 5mm within the fill length of lift), considering to pour the new
concrete slab.