background image

FIREBOX LININGS & THROAT
PLATE

The Beacon Multifuel stoves firebox has reflective
liners to the sides and rear. A specially shaped
throat plate which sits on the liners. If these are not
in place please refer to page 17 to install these.

MULTIFUEL GRATE

The static cast grate fitted to your Beacon multifu-
el stove, is designed to burn solid fuel briquettes,
well seasoned wood and peat. A combination of
these fuels can also be burnt, please note, the grate
requires no setting between the differing fuel types.

AIR INLET CONTROLS

Beacon multifuel stoves have two air inlets:
•The air wash system (so called because its
pre-heated high speed air washes across the inner
face of the door glass, keeping it clear), which
provides over draught, and
•The primary air inlet providing under draught to
the base of the fire chamber through the gap
between the body and the ash pit door.

PRIMARY AIR FOR MULTIFUEL

On Multifuel units primary air enters the appliance
through the gap between the body and the ash pit
door. The width of the gap is controlled by rotating
the door knob (if hot, with a suitable glove) anti-
clockwise to increase the the air inlet, clockwise to
reduce the air inlet, or seal the ash door
completely. 

Note: Opening or part opening of the ash door is
controlled by the "interlock" device located in the
front of the unit (refer to INTERLOCK section on
page 9).

AARROW AIRWASH SYSTEM  

The air wash has an internal sliding plate with slots,
housed in a cover plate, and is located above the fire
door. Sliding the control knob to the right as far as it
will go achieves the fully open position. 

Fig. 1 Fully Closed     Fig. 2 Fully Open

Sliding it to the left will shut off the air inlet slots
as shown in Fig. 1. Even when all the slots are com-
pletely shut a "bleed" of secondary air will be main-
tained ensuring that inflammable gases are burnt
off. 

DISASSEMBLE AIRWASH

The Beacon air wash may be disassembled for
cleaning or adjustment. To achieve this, the
following procedure should be followed:

This should only be carried out when the fire is cold
and unlit.

•Support Air Wash cover with one hand

•Move cover up by smartly tapping the bottom with   

a hammer. (Fig. 3)

•Remove assembly from appliance.

•Clean and/or adjust.

•Refit using reverse procedure.

Fig. 3

8

Beacon Multifuel Stoves

OPERATING INSTRUCTIONS  

Summary of Contents for Beacon

Page 1: ...Beacon Multifuel Stoves Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Rev 1 October 2005 AFS 1269 AARROW BEACON 75 SHOWN...

Page 2: ...which is why we are so confident in the reliability of our product Should you have any questions about our Beacon Stoves that are not covered in this manual please contact the Aarrow dealer in your a...

Page 3: ...Types 11 Lighting The Fire 11 12 Overnight Burning 12 Over Firing 13 Cleaning 13 Annual Maintenance 14 Accessories 15 INSTALLATION Page General Precautions 16 Handling 16 Hearth 16 Combustible Materi...

Page 4: ...BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPAR...

Page 5: ...properly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Arada Ltd produce a variety of applian...

Page 6: ...n Multifuel Stoves CHECK LIST Part Description Visual Aid not to scale Beacon 75 Beacon 77 2 Throat plate 1 1 3 Flue spigot 1 5 1 5 4 Hot plate 1 5 1 5 5 Ash pan 1 1 6 Operating tool 1 1 7 Rear liner...

Page 7: ...75 Beacon 77 Room Heater with Domestic Hot Water with add in boiler type N A N A Max Output to Room kW Max Output to Water kW N A N A Height mm 548 543 Width mm 476 482 Depth mm 345 345 Height to Cent...

Page 8: ...ating the door knob if hot with a suitable glove anti clockwise to increase the the air inlet clockwise to reduce the air inlet or seal the ash door completely Note Opening or part opening of the ash...

Page 9: ...DOOR TRIM Beacon fire doors are fitted with a brushed steel finish trim as standard This clips on to the small lugs at the top and bottom of the aperture in the cast iron fire door as a spring fit Wh...

Page 10: ...oor so that it is at a right angle to the front face of the fire Lift the fire door up off the hinges Gently tap the two hinge pins in a direction to compensate for the misalignment fig 7 Refit the do...

Page 11: ...nacite Plus Centurion Maxibrite Extracite Pureheat Blazebrite Taybrite Sunbrite Doubles Singles Anthracite Large Nuts and Welsh Dry Steam Coal Large Small Nuts Approval does not cover the use of other...

Page 12: ...ventilated during this time OVERNIGHT BURNING The appliance will burn overnight provided Sufficient fuel is placed in the firebox The controls are set correctly Excess draught is not present in the c...

Page 13: ...y clinker forming on the grate should be removed when cold OVER FIRING Do not over fire your appliance Using flammable liquids or too much wood or firing the fire at maximum for prolonged periods may...

Page 14: ...ged shut down period DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions such as burning at a low rate with damp wood or overnight burning the glas...

Page 15: ...n multifuel stove PAINT Matching aerosol paint to tone in any connecting flues pipes or surrounding metalwork INTERCHANGEABLE CANOPIES To fit the interchangeable canopy Fig 8 Remove the front clamps T...

Page 16: ...EARTH The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should proje...

Page 17: ...on the side landings behind the top edge of the grate Fig 11 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the side liners The lo...

Page 18: ...t it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the top of the flue also needs to comply with the Building Regulations The m...

Page 19: ...rth and fireplace installation Approved Document J of the Building Regulations for England and Wales is available from The Stationery Bookshops and can also be viewed at the ODPM website at www safety...

Page 20: ...20 Beacon Multifuel Stoves INSTALLATION...

Page 21: ...THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non insu...

Page 22: ...pliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been refurbished w...

Page 23: ...Manual AFS1269 AFS1269 AFS1019 AFS1019 AFS1083 AFS1083 AFS010 AFS010 AFS008 AFS008 AFS058 AFS058 AFS009 AFS009 2 Throat Plate 3 Grate 4 Hot Plate 5 Operating Tool 6 Ashpan 7 Flue Spigot Part Descripti...

Page 24: ...9 AFS088 AFS070 AFS089 AFS047 AFS047 AFS1077 AFS1077 9 Side Liner 10 Back Liner Set 11 Glass Replacement Kit Complete with Gasket 12 Glass Clips and Gasket 13 Hinge kit Comprises 2 Hinges 4 Fixings Pe...

Page 25: ...AFS1270 AFS1272 AFS094A AFS095 AFS1146 AFS1146 AFS997 AFS997 16 Main Door Assembly Complete with Handle Glass Gaskets Clips and Seal 17 Decorative Door Surround 18 Fire Door Locking Assembly 19 Aarro...

Page 26: ...ppliance being serviced and checked annually by a quali fied heating engineer The Manufacturers decision shall be final If your appliance proves to be defective as a result of faulty materials or work...

Page 27: ...Multifuel Stove that is not covered in this manual please contact your Aarrow retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as th...

Page 28: ...OPERATING TOOL Model Serial No I ve checked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on...