SERVICING
REPLACEMENT OF THE GLASS
IMPORTANT
When refitting the glass frame ensure the
original screws are used. Longer screws
may foul the Coal / Log set placement.
Ensure the appliance is cold.
Step 1a.
For rear flue appliance remove
canopy cover plate
Step 1b.
For top flue stove remove infill piece
Step 2.
Remove the fire doors Open and lift
off hinges (held shut by magnet)
Step 3.
Disengage locking levers, 1 per side
S
tep 4.
Lift the body and canopy off the chassis.
Refer to “Guide to manual handling” on page 3.
S
tep 5.
Remove the dummy fuel retainer, if the
glass is broken, suitable gloves should be worn
for protection.
Step 6.
Remove glass frame.
Remove any loose glass
Beware of any glass that my become loose
when removing frame.
Loosen but do not remove the 4 screws at the
base of the frame.
Remove all but 1 of the top retaining screws.
Remove the remaining top screw, the frame
and glass will now be loose and can be
removed.
The frame is slotted at the base for ease of
removal.