Ascotel® IntelliGate® 150/300 as of I7.9
Operation and Maintenance
163
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
If you need to stop the upload at any stage, click the "
Cancel
" button. The software
upload is then stopped and the current system software remains in operation.
Status display
The status display provides information with date and time indications on the cur-
rent software upload, including all the event messages output in connection with
the current software upload.
Upload log
Once an upload process is completed or if it is terminated prematurely, the settings
of the software upload including the data automatically entered in the log direc-
tory are printed out on the system printer.
See also:
Further information about uploading is available in Help of the Upload
Manager.
6. 2. 1. 3
Emergency Upload of the system software
An Emergency Upload has to be activated whenever a standard software upload is
not possible or has proved faulty. To ensure a successful Emergency Upload, pro-
ceed as follows:
The Emergency Upload is carried out via the LAN interface using the Upload Man-
ager:
1.
Set the system to boot mode using the pilot key (see
2.
Call up the AIMS Upload Manager.
3.
Enter user name and password (changed) of a user account.
Note: To perform the upload, the user account must be assigned an authoriza-
tion profile for which the "
FTP
" interface access is enabled (see
).
4.
Select the system type.
5.
Click the "
Add
" button and specify the zip file with the system software you re-
quire.
→
The software version you have added appears in the list box.
6.
Select the software version you want from the list box.