Ascotel® IntelliGate® 150/300 as of I7.9
196
Operation and Maintenance
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
6. 6. 1. 2
Event tables
Event tables list all the event messages the PBX is capable of generating (see
).
The frequency of event messages can range between "0" and "20".
The time period is indicated in hours, ranging between "0" and "672". The longest
time period "672" corresponds to 28 days or 4 weeks.
If the frequency of event messages is set to "0", the time period will also automati-
cally be set to "0". No event message is sent to a signal destination.
If the frequency of event messages is set to "1", the time period will automatically
be set to "0".
The event message will immediately be sent to the signal destinations.
If the time period is set to "0" hours, the frequency of the event message will auto-
matically be set to "1".
The event message will immediately be sent to the signal destinations.
There are 4 event tables in the Fault & Maintenance Manager. Each event table can
be individually configured and allocated to one of the 4 signal destinations. This
means it is possible to decide which event message – if any – should be sent to a
particular signal destination either immediately, with a delay or not at all.
Example
Tab. 97
Example of event table
In this example an event message is sent to the message destinations if there is a
"
Total synchronization loss
" event message when the PBX generates the event mes-
sage 10 times within 1 hour. With the event type"
System overload
", an event mes-
User does not answer
No answer to incoming DDI call from user on S
bus or AD2
DDI No., date, time
Wake-up call unanswered
Room wake-up call not answered
Room No., date, time
Wrong or missing wiring
adapter
There is no wiring adapter in the wiring
adapter slot or the wiring adapter fitted is
unsuitable.
Slot number, date, time
Event type
Frequency
Time period
Total Synchronization loss
10
1
System Overload
1
0
No response from network
0
0
Event/ error message
Trigger condition
Details